7. Changing the Fuses
The Model 252 has one set of fuses. The pair is on each leg of the incoming power. They are
accessible from the outside of the applicator.
Before attempting to service machinery, the machine must be turned off
and the power and air locked out.
The AC Main fuses are located in a tray in the power entry module. Remove the power cord
from the applicator, then, using a small flat blade screwdriver, pry the tray out of the power
entry module. The tray is located between the power cord socket and the power switch. Test
and replace any blown fuses with 5x20mm Slow Acting (or Time Lag) fuses of the appropriate
rating for the incoming voltage being used.
Содержание 252
Страница 1: ...Model 252 Label Printer Applicator Operator Technical Manual...
Страница 10: ...I GENERAL...
Страница 19: ...II OPERATING FUNDAMENTALS...
Страница 25: ...III INITIAL SETUP...
Страница 28: ...Model 252 Label Printer Applicator Operators Technical Manual 3 1 12 Declaration of Conformity...
Страница 98: ...Model 252 Label Printer Applicator Operators Technical Manual 0 IV CARE MAINTENANCE AND TROUBLESHOOTING...
Страница 116: ...Model 252 Label Printer Applicator Operators Technical Manual 0 V DRAWINGS AND DIAGRAMS...
Страница 128: ...Model 252 Label Printer Applicator Operators Technical Manual 12 Figure 8 Interface Board Layout...
Страница 160: ...VI COMPONENT INFORMATION...
Страница 161: ...Model 252 Label Printer Applicator Operators Technical Manual 1 MiniBeam Photocell...
Страница 162: ...Model 252 Label Printer Applicator Operators Technical Manual 2...
Страница 163: ...Model 252 Label Printer Applicator Operators Technical Manual 3...
Страница 164: ...Model 252 Label Printer Applicator Operators Technical Manual 4...