14
PRT-RDM2-PCB
Protege Mini 2 Reader Expander
Installation Manual | March 2015
5
Programmable Outputs
The Reader Expander has 8 Programmable Outputs (PGMs). These PGMs are used to activate bell sirens,
lighting circuits, door locks, relay accessory products, and other automation points.
5.1
Lock PGM Outputs (1 and 2)
Relays are provided on PGM output 1 and 2. These are used for the Lock 1 (PGM1 RD001:01) and Lock2
(PGM2 RD001:02) functions and are used to control electric door strikes and other lock control devices. The
lock relay will switch a maximum current of 7A resistive.
+
-
1N4007 Diode
12VDC Electric
Locking Device
+
-
Power Supply for
Locking Devices
Max 30VDC
NO
CO
M
N
C
Contact Rating 7A,
30VDC or 30VAC
Lock Output PGM1/2 Connection
5.2
Standard PGM Outputs (3 To 8)
The PGM outputs 3, 4, 5, 6, 7 and 8 on the Reader Expander are open collector outputs and switch to a
ground connection.
The PGMs have a default pre-programmed function as detailed in the following table and are used to control the
indicator and audible outputs on the attached reading device. These functions may be disabled by programming
the appropriate setting in the reader expander configuration.
PGM Number
Description
RDxxx:03
LED 1 (Green) Reader 1
RDxxx:04
LED 2 (Red) Reader 1
RDxxx:05
BEEPER Reader 1
RDxxx:06
LED 1 (Green) Reader 2
RDxxx:07
LED 2 (Red) Reader 2
RDxxx:08
BEEPER Reader 2