background image

PRT-RDM2-PCB 

Protege Mini 2 Reader Expander 

Installation Manual | March 2015   

13

 

 

4.2

 

Trouble Zone Inputs 

Each Reader Expander can monitor up to 16 trouble zones. Trouble zones are used to monitor the status of the 
Reader Expander and in most cases are not physically connected to an external zone. The following table 
details the trouble zones that are configured in the system and the trouble type and group that they activate. 

 

Zone Number 

Description 

Type 

Group 

RDxxx:01 

Module Tamper 

System Tamper 

System 

RDxxx:02 

AC Failure 

Power Fault 

General 

RDxxx:03 

Reserved 

None 

None 

RDxxx:04 

Aux Failure 

Power Fault 

General 

RDxxx:05 

Reserved 

None 

None 

RDxxx:06 

Door 1 Forced 

Forced Door 

Access 

RDxxx:07 

Door 2 Forced 

Forced Door 

Access 

RDxxx:08 

Door 1 Left Open 

Left Open 

Access 

RDxxx:09 

Door 2 Left Open 

Left Open 

Access 

RDxxx:10 

Reserved 

None 

None 

RDxxx:11 

Reserved 

None 

None 

RDxxx:12 

Reader 1 Tamper 

System Tamper 

System 

RDxxx:13 

Reader 2 Tamper 

System Tamper 

System 

RDxxx:14 

Door 1 Lockout 

Attempts 

Access 

RDxxx:15 

Door 2 Lockout 

Attempts 

Access 

RDxxx:16 

Module Offline 

Module Offline 

System 

Replace 'xxx' with the appropriate address of the Reader Expander that you are programming. 

 

Содержание Protege PRT-RDM2-PCB

Страница 1: ...PRT RDM2 PCB Protege Mini 2 Reader Expander Installation Manual...

Страница 2: ...produced photocopied or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and ma...

Страница 3: ...0 3 5 Door Lock Connection 11 4 Zone Inputs______________________________________________________________ 12 4 1 Zone Inputs 12 4 2 Trouble Zone Inputs 13 5 Programmable Outputs ______________________...

Страница 4: ...tralia ________________________________________________ 20 11 European CE and EN 50131 _______________________________________________ 21 12 Ordering Information ______________________________________...

Страница 5: ...distance of up to 900M 3000ft Further span can be achieved with the use of a network repeater module Locking a network prevents the removal substitution or addition of modules to the module network ef...

Страница 6: ...oles for the keyhole points in the top left and right locations This will allow you to screw in the screws and then hang the box on them adjusting the location to suit 3 Ensure a solid fixing point an...

Страница 7: ...ttery backed power supply unit such as the PRT PSU DIN or a networked module capable of supplying the required voltage to all devices on the RS485 network Warning The 12V N and N Communication input m...

Страница 8: ...ing an access door and entry exit door DO L2 D1 L1 BZ RED BLACK GREEN WHITE ORANGE BROWN BLUE YELLOW SHIELD R1 R1 R1 R1 R1 R1 R1 Standard Reader Connection Warning The shield connection on the card re...

Страница 9: ...DATA 1 input RED BLACK GREEN WHITE ORANGE BROWN BLUE YELLOW SHIELD RED BLACK GREEN WHITE ORANGE BROWN BLUE YELLOW SHIELD Entry Reader Exit Reader Data DO L2 D1 L1 BZ R1 R1 R1 R1 R1 R1 R1 DO L2 D1 L1 B...

Страница 10: ...d insert the inline 5 Volt regulator as shown in the diagram above 3 4 Door Contact Connection The Reader Expander allows the connection of up to 4 contacts for monitoring and controlling access contr...

Страница 11: ...Supply for Locking Devices Max 30VDC NO COM NC Contact Rating 7A 30VDC or 30VAC Door Lock Outputs i When using a door with an entry and exit reader the LOCK output should be connected to LOCK 1 and en...

Страница 12: ...When using a zone with the EOL resistor configuration the controller generates an alarm condition when the state of a zone changes between open and closed and generates a tamper alarm condition when...

Страница 13: ...m Tamper System RDxxx 02 AC Failure Power Fault General RDxxx 03 Reserved None None RDxxx 04 Aux Failure Power Fault General RDxxx 05 Reserved None None RDxxx 06 Door 1 Forced Forced Door Access RDxxx...

Страница 14: ...7 Diode 12VDC Electric Locking Device Power Supply for Locking Devices Max 30VDC NO COM NC Contact Rating 7A 30VDC or 30VAC Lock Output PGM1 2 Connection 5 2 Standard PGM Outputs 3 To 8 The PGM output...

Страница 15: ...ted ONLY if the reader expander is operating offline and the mode of offline operation prevents this card from being allowed access 1 Long Beep 1 Short Beep Access Denied Card Number Not Known The car...

Страница 16: ...eader Expander will automatically default the internal configuration and require a network update See the Protege System Reference Manual for information on performing a module update 1 ADDRESS 1 2 AD...

Страница 17: ...a non standard mode When the Fault indicator is FLASHING the Reader Expander is operating in boot mode awaiting firmware update When the Fault indicator is ON the Reader Expander is in error state an...

Страница 18: ...xpander is not compatible with the system controller To clear this error update the module using the module update application 3 Address Too High The Reader Expander address is above the maximum numbe...

Страница 19: ...Output Voltage 12VDC 700mA Typical Electronic Shutdown at 1 1A Operating Current 40mA Typical 110mA Max All Relays Activated Low Voltage Cut out 8 7VDC Low Voltage Restore 10 5VDC Communication RS 48...

Страница 20: ...New Zealand and Australia The C Tick compliance label indicates that the supplier of the device asserts that it complies with all applicable standards The SCN establishes a traceable link between a de...

Страница 21: ...50131 1 the following points should be noted Ensure for Grade 3 compliant systems the minimum PIN length is set for 6 digits To comply with EN 50131 1 Engineer access must first be authorised by a use...

Страница 22: ...should not be programmed to more than 45 seconds To comply with EN 50131 1 the Bell Cut Off Time should be programmed between 02 and 15 minutes EN 50131 1 requires that detector activation LEDs shall...

Страница 23: ...following product codes when placing an order for the Protege Mini 2 Reader Expander PRT RDM2 PCB To order the Reader Expander in a cabinet order the CAB MED steel cabinet complete with transformer a...

Страница 24: ...the products and because the products may be used in conjunction with products not manufactured by ICT ICT cannot guarantee the performance of the security system ICT s obligation and liability under...

Страница 25: ...information below Integrated Control Technology P O Box 302 340 North Harbour Post Centre Auckland New Zealand 11 Canaveral Drive Albany North Shore City 0632 Auckland New Zealand Phone 64 9 476 7124...

Страница 26: ...echnology Ltd nor its employees shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the Integ...

Отзывы: