Proper

 

Use

The

 

IPM5

/

IPW5

 

device

 

is

 

designed

 

for

 

the

 

evaluation

 

and

 

display

 

of

 

sensor

 

signals.

 

With

 

the

 

setpoints

 

it

 

is

 

possible

 

to

 

perform

 

simple

 

control

 

tasks.

Danger!Careless use or improper operation can result in

personal injury and/or damage the equipment.

Control

 

of

 

the

 

device

The

 

panel

 

meters

 

are

 

checked

 

before

 

dispatch

 

and

 

sent

 

out

 

in

 

perfect

 

condition.

 

Should

 

there

 

be

 

any

 

visible

 

damage,

 

we

 

recommend

 

close

 

examination

 

of

 

the

 

packaging.

 

Please

 

inform

 

the

 

supplier

 

immediately

 

of

 

any

 

damage.

Installation

The

 

IPM5

/

IPW5

 

device

 

must

 

be

 

installed

 

by

 

a

 

suitably

 

qualified

 

specialist

 

(e.g.

 

with

 

a

 

qualification

 

in

 

industrial

 

electronics).

Notes

 

on

 

installation

• There must be no magnetic or electric fields in the vicinity of the device, e.g. due to
transformers, mobile phones or electrostatic discharge.

The fuse rating of the supply voltage should not exceed a value of 0.5A N.B. fuse!

• Do not install

inductive consumers

(relays, solenoid valves etc.) near the device and

suppress

any interference with the aid of RC spark extinguishing combinations or free-wheeling

diodes.

• Keep input, output and supply lines separate from one another and do not lay them parallel
with each other. Position “go” and “return lines” next to one another. Where possible use twisted
pair. So, you receive best measuring results.

• Screen off and twist sensor lines. Do not lay current-carrying lines in the vicinity. Connect the

screening on one side

on a suitable potential equaliser (normally signal ground).

• The device is not suitable for installation in areas where there is a risk of explosion.

• Any electrical connection deviating from the connection diagram can endanger human life
and/or can destroy the equipment.

• Do not install several devices immediately above one another or in an extremely thermal
isolated housing. Due to the internal heat dissipation of the decives, the recommended ambient
temperature can be excessed.

• The terminal area of the devices is part of the service. Here electrostatic discharge needs to be
avoided. Attention! High voltages can cause dangerous body currents.

• Galvanic isolated potentials within one complex need to be placed on a appropriate point
(normally earth or machines ground). So, a lower disturbance sensibility against impacted
energy can be reached and dangerous potentials, that can occur on long lines or due to faulty
wiring, can be avoided.

3. Safety advices

5

3. Safety advices

Содержание IPM5

Страница 1: ...2 of measuring range are noise free high long term and temperature stability 5 digit digital display with range from 9999 to 99999 digits free scaling and setting of decimal point alignment of a senso...

Страница 2: ...ndex D version D 4 wire sensor M 6 wire sensor W Switching points 0 no switching points Number of digits 2 2 relay outputs 5 digits 5 4 4 relay outputs Interface Mechanical options none 0 7 IP65 foil...

Страница 3: ...calibration 6 4 3 Adjustment with 80 calibration IPM5 6 4 4 Sensitivity recognition 6 4 5 Automatical calibration 6 4 6 Taring 6 4 7 Hold function 6 5 Interfaces RS232 RS485 7 Programming 7 1 Program...

Страница 4: ...of 4 relays are available to monitor the threshold values Data from and to the device can be transmitted via the serial interface The IPM5 has a 4 wire connection with an additional calibration contac...

Страница 5: ...ching points 1 LED per switching point Overflow horizontal bars at the top Underflow horizontal bars at the bottom Display time 0 1 to 10 0 seconds Strain gauge input Measuring range Metering precisio...

Страница 6: ...pecific ASCII RS232 9600 Baud no parity 8 data bit 1 stop bit Cable length max 3 m RS485 9600 Baud no parity 8 data bit 1 stop bit Cable length max 1000 m Power pack Voltage supply 100 240 VAC 50 60 H...

Страница 7: ...e wheeling diodes Keep input output and supply lines separate from one another and do not lay them parallel with each other Position go and return lines next to one another Where possible use twisted...

Страница 8: ...5 IPW5 Gap for physical unit 1 After removing the fixing elements insert the device 2 Check the seal to make sure it fits securely 3 Click the fixing elements back into place and tighten the clamping...

Страница 9: ...or strip RS232 41 42 43 GND RS TxD RxD or RS485 41 42 43 GND RS Data B Data A The lines of the RS232 interface need to be connected 1 1 TxD to TxD and RxD to RxD RxD TxD GND RxD TxD GND IPW5 IPM5 PC o...

Страница 10: ...th a calibration wire CAL Mass pressure sensors which frequently have an additional wire for the artificial unbalance 80 of the bridge can be automatically calibrated via terminal 7 Examples of the co...

Страница 11: ...e 100 240 VAC 9 5 Electrical connection 100 240 VAC 2 3 4 5 6 7 8 9 10 11 In 2 In 3 In 4 In 5 In 6 In 7 Strain gauge input Analog output Digital input In 1 1 12 L 13 Auxiliary voltage 14 N Din 2 3 4 5...

Страница 12: ...ustable Unit C F Pt100 thermocouple Switchpoint displays 2 Optical limit value report 4 LED red Keys 5 6 7 and 3 Programming mode Increase range of value Reduce range of value Select next lower progra...

Страница 13: ...in value Erase the value that is shown in the display by simultaneously operating the and keys The erasure is acknowledged by horizontal bars The content of the memory will be lost with switching off...

Страница 14: ...on below the threshold and switched off on reaching the threshold Switching on delay The relay S1 S4 is on 10 seconds after reaching the threshold briefly exceeding the threshold does not lead to the...

Страница 15: ...nt value with possible taring the min value the max value the Hold value or the absolute value without possible taring The analogue output is updated in the cycle of the measuring time PN14 and has at...

Страница 16: ...he second run the calibration is carried out in the relevant measuring zone The procedure is as follows Sensitivity recognition Display of SEnS for the entire process Amplification of the measuring in...

Страница 17: ...offset nor end value are within the measuring range CErr2 if the end value is not at least 1 of measuring range greater than offset CErr3 if the end value is outside the measuring range CErr4 if the...

Страница 18: ...ransmitted so that the output can be displayed directly on a terminal or processed by a SPS Zeros at the front are suppressed during transmission With an overflow or underflow the display transmits ho...

Страница 19: ...ommand is sent the display will acknowledge this with an via the interface Under normal conditions the display does not send an acknowledgement back Only when the value is called up or the acknowledge...

Страница 20: ...number Change to the next program number Program number is displayed Change read the deposited parameters in the program Flashing of the least significant digit Save parameter Save the complete range...

Страница 21: ...d parameters are displayed In this case it is 75 640 7 1 Programming procedure The entire programming of the IPM5 IPW5 is done by the steps described below Change to programming mode Push the P key to...

Страница 22: ...sume the figure has to be changed from 75 640 to 75 000 Briefly push the P key to move to the next digit The 4 begins to flash Change the figure by pushing or key to change the digit from 4 to 0 Brief...

Страница 23: ...sensors and the corresponding display value programmed under the following program numbers PN101 PN105 The sensor signal must be parameterised with a strictly monotonous rising configuration A gap of...

Страница 24: ...ller than the offset setting PN2 It must differ from its measured value by at least 1 of the measuring range of the programmed offset value in PN2 If a standard sensor has been selected PN0 2 3 or 4 t...

Страница 25: ...conds With the static taring PN6 5 the taring operation is performed with an upward slope and held until the signal is taken away again After that the absolute value is displayed This function is espe...

Страница 26: ...ered direct after returning from the programming mode by confirming PN9 Calibration point PN10 Calibration point PN10 gives the percentage target value for the end value calibration As a rule 100 00 i...

Страница 27: ...the trigger is returned again PN16 8 has a special status because here no min max values can be called up via or key This mode is particularly necessary with calibrated balances due to the possibility...

Страница 28: ...ameter 59 95 X X X X X X Set value for taring 7 X X X X X Interfaces parameter Device option 32 34 X X X X Analog output parameter Device option 20 23 X X X X Measuring input parameter 0 18 X X X Line...

Страница 29: ...e various parameters is given in section 6 2 Relays The program numbers are also available when no relays are carried out in the unit In such cases only the relevant alarm LED light up on the front of...

Страница 30: ...99 0 2 3 Places after decimal point 0 4 none 2 5 Offset displacement 9999 99999 0 2 6 Taring function 0 no taring 1 permanent taring 2 transient taring 3 quick transient taring without report 4 perman...

Страница 31: ...1 10 0 1 0 2 14 Measuring time 0 01 10 00 1 00 2 15 Display mode 1 current measurand 2 min value 3 max value 4 Hold value 5 absolute value 1 2 16 Trigger for display change 0 none 1 absolute value st...

Страница 32: ...at exceedance of output area PN20 21 4 switch to smallest value 0x0000 at exceedance of output area PN20 21 5 switch to final value at converter over underflow wire break bars 6 switch to initial val...

Страница 33: ...0 no flashing 1 flashes at 1 2 flashes at 2 3 flashes at 3 4 flashes at 4 5 flashes at 1 or 2 6 flashes at 3 or 4 7 flashes at 1 2 3 or 4 0 5 Switchpoint 1 60 Switchpoint 1 0 deactivated 1 current me...

Страница 34: ...rror 1 5 81 Threshold 9999 99999 1000 6 82 Hysteresis 0 99999 0 5 83 Operation type quiescent current operating current 0 quiescent current 1 operating current 1 5 84 Switching delay 0 0 10 0 seconds...

Страница 35: ...return the unit to a defined basic state a reset can be carried out to the default values The following procedure should be used Switch off the power supply Press button P Switch on the power supply a...

Страница 36: ...n 9999 3 The display shows HELP in the 7 segment display The device located an error in the configuration memory carry out a reset to default values and reconfigure the device according to your applic...

Отзывы: