![ICS IPM5 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/ics/ipm5/ipm5_user-manual_3538998031.webp)
PN
Function
Range of value
De-
fault
User-
level
10
Balance point in %
IPM5
IPW5
0.01 … 100.00
0.01 … 100.00
80.00
100.0
2
11
Trigger for calibration
0 = none
1 = digital input
2 = 4th key
3 = digital input or 4th key
4 = system start
5 = combination 1 & 4
6 = combination 2 & 4
7 = combination 3 & 4
0
2
12
Transducer calibration
0 = no transducer calibration
1 = at system start
2 = every 200 measurements
0
2
General settings
13
Display time
0.1…10.0
1.0
2
14
Measuring time
0.01…10.00
1.00
2
15
Display mode
1 = current measurand
2 = min-value
3 = max-value
4 = Hold-value
5 = absolute value
1
2
16
Trigger for display change
0 = none
1 = absolute value static on digital
input
2 = absolute value static on 4th key
3 = absolute value static on 1 or 2
4 = none
5 = conversion value on digital input
0
2
17
Conversion value equals with PN1
-9999…99999
1
2
18
Decimal point for conversion value
0…4
0
2
19
Display brightness
0…9 (0=bright / 9=dark)
3
7
Analog output
20
Final value / fullscale
-9999…99999
10000
4
21
Initial value / offset
-9999…99999
0
4
29