![ICS IPM5 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/ics/ipm5/ipm5_user-manual_3538998033.webp)
PN
Function
Range of value
De-
fault
User-
level
Safety settings
50
Programing lock
0000…9999
0000
8
51
Release code for all parameter
0000…9999
0000
0
52
User level
0…8
8
0
53
Release code for user level
0000 = user level always released
0000…9999
0000
0
Threshold behaviour of LED-display
59
Display flashing (approx. 0.5 seconds)
No flashing
Flashing at switchpoint 1
Flashing at switchpoint 2
Flashing at switchpoint 3
Flashing at switchpoint 4
Flashing at switchpoints 1 and 2
Flashing at switchpoints 3 and 4
Flashing at switchpoints 1, 2, 3 and 4
0 no flashing
1 flashes at 1
2 flashes at 2
3 flashes at 3
4 flashes at 4
5 flashes at 1 or 2
6 flashes at 3 or 4
7 flashes at 1, 2, 3 or 4
0
5
Switchpoint 1
60
Switchpoint 1
0 = deactivated
1 = current measurand
2 = min-value
3 = max-value
4 = Hold-value
5 = absolute value
6 = sensor error
1
5
61
Threshold
-9999…99999
1000
6
62
Hysteresis
0…99999
1
5
63
Operation type quiescent current / operating
current
0 = quiescent current
1 = operating current
1
5
64
Switching delay
0.0…10.0 seconds
0.0
5
65
Type of delay
0 = none
1 = switching-on delay
2 = switching-off delay
3 = switching-on/-off delay
1
5
Switchpoint 2
70
Switchpoint 2
0 = deactivated
1 = current measurand
2 = min-value
3 = max-value
4 = Hold-value
5 = absolute value
6 = sensor error
1
5
31