TABLE 4.1
Technical specifications
TABLE 5.1
Air delivery - CFM with air filter
SPEED
0.1"
0.2"
0.3"
0.4"
0.5"
0.6"
0.7"
0.1"
0.2"
0.3"
0.4"
0.5"
0.6"
0.7"
LOW
940
880
820
760
700
640
580
1148
1116
1084
1052
1020
988
956
MED-LO
1054
978
902
826
750
674
598
1366
1362
1358
1354
1350
1346
1342
MED-HI
1144
1108
1072
1036
1000
964
928
1676
1642
1608
1574
1540
1506
1472
HIGH
1444
1408
1372
1336
1300
1264
1228
2250
2150
2050
1950
1850
1750
1650
OLR105A12C
OLR160B20C
EXTERNAL STATIC PRESSURE WITH AIR FILTER
Model :
Firing rate (USGPH)
0.50
0.63
0.75
0.72
0.85
0.97
1.14
Input (BTU/h)
70 000
88 200
105 000
100 800
119 000
135 800
159 600
Heating capacity, chimney installation (BTU/h)
59 200
73 000
87 800
99 000
111 000
129 000
Heating capacity, side-w all installation (BTU/h)
59 400
73 200
88 200
84 200
97 000
110 000
127 000
Minimum - maximum temperature rise
Flue draft, (Chimney), (Side-w all)
Overfire pressure (chimney), (Side-w all)
BECKETT BURNER, CHIMNEY INSTALLATION
Burner tube insertion lenght (inches)
Low firing rate baffle
Yes
Yes
No
No
No
No
Static disc, model
2 3/4 #3383 2 3/4 #3383 2 3/4 #3383
2 3/4 #3383 2 3/4 #3383 2 3/4 #3383
Nozzle (Delavan)
0.50 - 70A
0.50 - 70A
0.60 - 70B
0.75 - 70B
0.85 - 70B
1.00 - 70B
Pump pressure (PSIG)
100
156
156
130
130
130
Combustion air adjustment ( band/shutter )
0 / 4.5
0 / 8
0 / 7.5
0 / 5
0 / 6.5
0 / 10
AFUE % (From CSA B212 standard and Canadian regulation)
83.9
82.4
80.7
82.2
81.5
80.3
AFUE % (From ASHRAE 103 standard and US regulation)
81.5
81.0
80.3
82.2
81.5
80.3
RIELLO BURNER, CHIMNEY INSTALLATION
Burner tube insertion lenght (inches)
Nozzle (Delavan)
0.40 - 60A
0.50 - 60A
0.60 - 60A
0.75 - 70B
0.85 - 70B
1.00 - 70B
Pump pressure (PSIG)*
156
156
156
130
130
130
Combustion air adjustment (turbulator / damper)
0 / 2
0 / 3
0 / 4
1 / 2
1 / 2.5
1 / 3
AFUE % (With the oil vent damper option)
85.4 ‡
AFUE % (From CSA B212 standard and Canadian regulation)**
85.7‡
84.8
83.7
83.5
82.4
80.6
AFUE % (From ASHRAE 103 standard and US regulation)**
85.1‡
83.8
82.7
82.2
81.5
80.3
BECKETT BURNER, SIDE-WALL INSTALLATION
Burner tube insertion lenght (inches)
Nozzle (Delavan)
0.50 - 60W 0.50 - 60W 0.60 - 60W
0.75 - 70B
0.85 - 70B
1.00 - 70B
Pump pressure (PSIG)
130
140
160
130
130
130
Combustion air adjustment (screw / dial) or (dial only)
3 / 1.5
3 / 3
3 / 4.5
2.75
4.25
6.75
AFUE % (From CSA B212 standard and Canadian regulation)
83.9
82.4
80.7
82.2
81.5
80.3
AFUE % (From ASHRAE 103 standard and US regulation)
81.5
81.0
80.3
82.2
81.5
80.3
RIELLO BURNER, SIDE-WALL INSTALLATION
Burner tube insertion lenght (inches)
Nozzle (Delavan)
0.50 - 60W 0.50 - 60W
0.60 - 60W 0.75 - 70B
0.85 - 70B
1.00 - 70B
Pump pressure (PSIG)
135
140
155
130
130
130
Combustion air adjustment (turbulator / damper)
0 / 3
0 / 6
0 / 7.5
1 / 3
1 / 4
2 / 4.5
AFUE % (From CSA B212 standard and Canadian regulation)
85.7‡
84.8
83.7
83.5
82.4
80.6
AFUE % (From ASHRAE 103 standard and US regulation)
85.1‡
83.8
82.7
82.2
81.5
80.3
Volts - Hertz - Phase
Operating voltage range (Volts)
Electrical load (Amps)
Minimum ampacity for w iring sizing
Max. fuse size (Amps)
Control transformer
Ext. control pow er available, cooling and accessories
Blow er speed at 0.50" W.C. static pressure
MED-LO
MED-HI
HIGH
HIGH
MED-LO
MED-HI
HIGH
Blow er speed at 0.25" W.C. static pressure
LOW
MED-HI
MED-HI
MED-HI
MED-LO
MED-HI
MED-HI
Maximum cooling, speed
LOW
MED-LO
MED-HI
HIGH
MED-LO
MED-HI
HIGH
Maximum cooling, tons @ 0.50" W.C.
1.5
2
2.5
3
3.5
4
5
Motor (HP) / number of speeds
Blow er w heel size (in.)
ELECTRICAL SYSTEM
BLOWER DATA
5 3/16''
7''
115 - 60 - 1
115 - 60 -1
104 - 132
104 - 132
12.2
15.7
5 3/16''
7''
4 15/16''
6 5/8''
AFII-85
AFII-150
40-BF3 w ith AL1009 post purge control
40-BF5
OLR105A12D
OLR160B20C
11 - 24°C (52 - 75°F)
10 - 27°C (50 - 80°F)
RATING AND PERFORMANCE
(-0.035" to -0.06") (+0.04" to +0.16")
(-0.035" to -0.06") (+0.04" to +0.22")
(0.00" to +0.035") (+0.10" to +0.25")
(-0.00" to +0.04") (+0.10" to +0.25")
AFG w ith F0 head
AFG w ith F3 head
40-F3
40-F5
5 1/8''
6 5/8''
13.7
18.1
15
20
40 VA
40 VA
30 VA
30VA
1/3 HP / 4 speeds
3/4 HP / 4 speeds
10 X 10
12 X 10
23
* INPUT & OUTPUT ADJUSTMENT
Pump pressure can be adjusted to maintain proper firing rate.
Adjust the total flue gas temperature between 400˚F and 575˚F (330˚F and 505˚F net approximately)
Adjust fan speed for air temperature rise of 55˚ to 85˚F.
** AFUE value established after minimum 20 hours of operation.
‡ =
Содержание OLR105A12D
Страница 25: ...DNS 0571 Rev C DNS 0573 Rev C FIGURE 5 1 Model OLR105A12D FIGURE 5 2 Model OLR160B20C 26...
Страница 26: ...FIGURE 5 3 Model OUF105A12C FIGURE 5 4 Model OUF160B18C DNS 0572 Rev D DNS 0568 Rev C 27...
Страница 27: ...FIGURE 5 5 Model OLF105A12C DNS 0570 Rev C FIGURE 5 6 Model NOUF105A12D DNS 0674 Rev E 28...
Страница 28: ...FIGURE 5 7 Model NOLF105A12D DNS 0676 Rev D 29...
Страница 29: ...FIGURE 6 Wiring diagram OLR105A12D OLR160B20C OUF105A12C NOUF105A12D OUF160B18C OLF105A12C NOLF105A12D 30...
Страница 30: ...COMPONENTS AND REPLACEMENT PARTS 31...
Страница 31: ...PARTS LIST Model OLR105A12D B50031 B 32...
Страница 33: ...PARTS LIST Model OLR160B20C B50032 C 34...
Страница 35: ...PARTS LIST Model OUF105A12C B50033 B 36...
Страница 37: ...PARTS LIST Model OUF160B18C B50034 D 38...
Страница 39: ...PARTS LIST Model OLF105A12C B50035 B 40...
Страница 41: ...PARTS LIST Model NOLF105A12D B50037 B 42...
Страница 43: ...PARTS LIST Model NOUF105A12D B50036 B 44...