1.9 Configuration Tables
Baud Rate Setting (CC)
7 6 5 4 3 2 1 0
Data Baud
Key Description
Baud Baud
Rate
03: 1200
04: 2400
05: 4800
06: 9600
07: 19200
08: 38400
09: 57600
0A: 115200
Data Data
Format
0: eight data bits, no parity, and one stop bit
1: eight data bits, no parity, and two stop bit
2: eight data bits, even parity, and one stop bit
3: eight data bits, odd parity, and one stop bit
Type Setting (TT)
For tM modules, the type code is fixed to 40.
tM Series DIO User Manual, Rev: A1.3 7PH-013-A13