17
OTHER FUNCTIONS
17-23
■
CI-V information (Continued)
D
Command table
Cmd. Sub
cmd.
Data
Description
00
see p. 17-24 Send operating frequency for transceive
01
see p. 17-24 Send operating mode for transceive
03
see p. 17-24 Read operating frequency
04
see p. 17-24 Read operating mode
05
see p. 17-24 Send operating frequency
06
see p. 17-24 Send operating mode
07
Select the VFO mode
D0
Select A band
Dualwatch: Set the Main band as the A band
Single watch: Select the A band
D1
Select B band
Dualwatch: Set the Main band as the B band
Single watch: Select the B band
0C
see p. 17-24 Read frequency offset*
1
0D
see p. 17-24 Send frequency offset
0F
Read duplex setting
(10= simplex, 11= DUP–, 12= DUP+)
10
Set simplex operation
11
Set DUP– operation
12
Set DUP+ operation
11
00
Send/read attenuator OFF (AIR band)
30
Send/read 30 dB attenuator (AIR band)
14
01 see p. 17-24 Send/read audio output level
03 see p. 17-24 Send/read squelch level
0A see p. 17-24 Send/read RF power setting
0B see p. 17-24 Send/read external microphone gain.
16 see p. 17-24 Send/read VOX gain.
15
01
00
Read noise/S-meter squelch status (squelch
close)
01
Read noise/S-meter squelch status (squelch
open)
02
0000 to
0255
Read S-meter level (0000= S0, 0170= S9)
05
00
Read tone squelch and RF squelch status
(squelch close)
01
Read tone squelch and RF squelch status
(squelch open)
11
0000 to
0255
Read RF power meter
( 0005= S-LOW, 0026= LOW1, 0051= LOW2,
0128= MID, 0255= HIGH)
16
42
00
Send/read Repeater tone OFF
01
Send/read Repeater tone ON
43
00
Send/read Tone squelch OFF
01
Send/read Tone squelch ON
02
Send/read Reversed Tone squelch ON
46
00
Send/read VOX function OFF
01
Send/read VOX function ON
4B
00
Send/read DTCS OFF
01
Send/read DTCS ON
02
Send/read Reversed DTCS ON
59
00
Send/read Sub band OFF
01
Send/read Sub band ON
5B
00
Send/read DSQL/CSQL OFF (DV mode only)
01
Send/read DSQL ON (DV mode only)
02
Send/read CSQL ON (DV mode only)
5C
00, 01, 02 Send/read GPS TX mode
(00= OFF, 01= D-PRS, 02= NMEA)
5D
00 to 09
Send Tone setting
( 00= OFF, 01= TONE, 02= TSQL, 03=DTCS,
04=TSQL-R, 05=DTCS-R, 06=DTCS(T),
07=TONE(T)/DTCS(R), 08=DTCS(T)/TSQL(R),
09=TONE(T)/TSQL(R))
18
00
Turning the transceiver power OFF
01
Turning the transceiver power ON*
2
19
00
Read transceiver ID.
Cmd. Sub
cmd.
Data
Description
1B
00
see p. 17-24 Send/read Repeater tone frequency
01
see p. 17-24 Send/read Tone squelch frequency
02
see p. 17-25 Send/read DTCS code and polarity
07
see p. 17-25 Send/read CSQL code (DV mode)
1C
00
00
Send/read Transceiver’s status (RX)
01
Send/read Transceiver’s status (TX)
1F
00
see p. 17-25 Send/read DV MY call sign
01
see p. 17-25 Send/read DV TX call signs
02
see p. 17-25 Send/read DV TX message
20 00 00
00*
3
Send/read Auto DV RX Call signs output OFF
01*
3
Send/read Auto DV RX Call signs output ON
01
see p. 17-26 Output DV RX Call signs
02
see p. 17-26 Read DV RX Call signs
01 00
00*
3
Send/read Auto DV RX message output OFF
01*
3
Send/read Auto DV RX message output ON
01
see p. 17-26 Output DV RX message
02
see p. 17-26 Read DV RX message
02 00
00*
3
Send/read Auto DV RX status output OFF
01*
3
Send/read Auto DV RX status output ON
01
see p. 17-25 Output DV RX status
02
see p. 17-25 Read DV RX status
03 00
00
Send/read Auto DV RX GPS/D-PRS data
output OFF
01
Send/read Auto DV RX GPS/D-PRS data
output ON
01 see p. 17-26
Output DV RX GPS/D-PRS data for transceive
02 see p. 17-26
Read DV RX GPS/D-PRS data for transceive
04 00
00
Send/read Auto DV RX GPS/D-PRS mes-
sage output OFF
01
Send/read Auto DV RX GPS/D-PRS mes-
sage output ON
01 see p. 17-28 Output DV RX GPS/D-PRS message for transceive
02 see p. 17-28 Read DV RX GPS/D-PRS message for transceive
22 00
see p. 17-28 Send/read DV TX data (Up to 30 bytes)
01 00
00
Send/read Auto DV RX data output OFF
01
Send/read Auto DV RX data output ON
01 see p. 17-28 Send/read DV RX data (Up to 30 byte)
02
00, 01
Send/read DV data TX setting (00=PTT, 01=Auto)
03
00, 01
Send/read DV fast data setting (00=OFF, 01=ON)
04
00, 01
Send/read GPS Data Speed setting
(00=Slow, 01=Fast)
05
00~10
Send/read TX Delay (PTT) setting
(00=OFF, 01=1 sec. ~ 10=10 sec.)
*
1
: Less than 100 Hz is omitted.
*
2
: When sending the power ON command (18 01), the command
“FE” must be sent before the basic format.
• 19200bps: 50 • 9600bps: 26 • 4800bps: 14
• 1200bps: 5
• 300bps: 3
q
w
e
r
t
u
F
F E
×14
6
8
E
F
E
E
1
0
8
1
O
D
F
Example: When operating with 4800 bps
q
Preamble code (fixed)
w
Transceiver’s default address
e
Controller’s default address
r
Command number
t
Sub command number
u
End of message code (fixed)
*
3
: Output setting is automatically turned OFF after turning the power
OFF, then ON.
Previous view