11-17
11
SET MODE
D
D
Load option set mode
Selects file loading condition from All and Select.
(default: Select)
• All
: Loads and sets the all following contents.
• Select : Loads and sets the selected contents only.
LOAD Contents
Select
Selects the reference signal setting loading condition
YES and NO. (default: NO).
• YES
: Loads and sets the reference signal setting.
• NO
: Use the original reference signal setting.
REF IN/OUT, REF Adjust
NO
Selects the IP address and subnet mask setting load-
ing condition YES and NO. (default: NO).
• YES
: Loads and sets the IP address and subnet
mask setting.
• NO
: Use the original IP address and subnet
mask setting.
IP Address, Subnet Mask
NO
Selects the CI-V address setting loading condition
YES and NO. (default: NO).
• YES
: Loads and sets the CI-V address setting.
• NO
: Use the original CI-V address setting.
CI-V Address
NO
Selects memory channel contents and other settings
loading condition YES and NO. (default: YES).
• YES
: Loads and sets memory channel contents
and other settings.
• NO
: Use the original memory channel contents
and other settings.
Other Memory & Settings
YES
Selects the voice RX memory loading condition YES
and NO. (default: NO).
• YES
: Loads and sets the voice RX memory.
• NO
: Use the original the voice RX memory.
Voice RX Memory
NO
Содержание IC-R9500
Страница 1: ...COMMUNICATIONS RECEIVER iR9500 Instruction Manual A 6553H 1EX Printed in Japan 2007 Icom Inc...
Страница 10: ......
Страница 11: ...1 1 PANEL DESCRIPTION Section 1 Front panel 1 2 Rear panel 1 8 LCD display 1 10 Screen menu arrangement 1 12...
Страница 64: ......
Страница 82: ......
Страница 90: ......
Страница 120: ......
Страница 160: ......
Страница 172: ......
Страница 173: ...14 1 SPECIFICATIONS AND OPTIONS Section 14 Specifications 14 2 D General 14 2 D Receiver 14 3 Options 14 4...