4 - 2
4-2 FP-561 TRANSMITTER ADJUSTMENT
OUTPUT
POWER
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT
LOCATION
UNIT
ADJUST
1
2
• Connect a transducer to the
[TRANSDUCER] connector.
• Mode
: [SOUNDER]
• Frequency
: [H]
• Depth range
: 640 m
• Frequency
: [L]
MAIN
Connect an oscillo-
scope between pin
3 and pin 5 of J2.
880–1320 Vp-p
at maximum wave
point
Verify
Verify
4-4 FP-561 WATER TEMPERTURE ADJUSTMENT
WATER
TEMPERATURE
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT
LOCATION
UNIT
ADJUST
1 •
Connect a 10 k
Ω
resistor
between pin 6 and pin 7 of the
[TRANSDUCER] connector J2.
Display
25.0 ˚C
LOGIC
R131
*This output level of the standard signal generator (SSG) is indicated as SSG’s open circuit.
4-3 FP-561 RECEIVER ADJUSTMENT
RECEIVE
SENSITIVITY
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT
LOCATION
UNIT
ADJUST
1
2
3
• Mode
: [SOUNDER]
• Frequency
: [H]
• Depth range
: 5 m
• STC
: [1]
• Connect a standard signal gener-
ator to the [TRANSDUCER] con-
nector J2 via the coupler and set
as:
Fequency
: 200 kHz
Level
: 1 mV (–47 dBm)
• Frequency
: [L]
• Set an SSG as :
Frequency
: 50 kHz
Level
: 1 mV (–47 dBm)
• Set an SSG as :
Frequency
: 50 kHz
Level
: 100 mV (–7 dBm)
MAIN
Connect a DC volt-
meter or oscillo-
scope to the check
point “RSSI”.
Maximum DC voltage
MAIN
L1
L6
R99