![ICM Controls ICM1511 Series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/icm-controls/icm1511-series/icm1511-series_custom-options-manual-and-installation-instructions_610899017.webp)
Preliminary Steps
1. Check wiring connections and power supply.
2. Make sure power is on to controls.
3. Make sure limit control is closed.
4. Check contacts between ignitor and the electrodes.
5. Check the oil pump pressure.
6. Check the piping to the oil tank.
7. Check the oil nozzle, oil supply and oil filter.
Check Oil Primary Control
If the trouble is not in the burner or ignition hardware, check the oil primary control by
using the following equipment:
1. Screwdriver.
2. Voltmeter (0 to 150 VAC range).
3. Insulated jumper wire with both ends stripped.
WARNING: Electrical Shock Hazard. Can cause severe injury, death or property damage.
Troubleshoot with the system powered. Be careful to observe all precautions to
prevent electrical shock or equipment damage.
Содержание ICM1511 Series
Страница 23: ...This page left blank intentionally ...