Warning! Electrical Shock Hazard!
• Can cause severe injury, death or property damage.
• Disconnect power supply before beginning installation to prevent electrical shock or
equipment damage. More than one disconnect may be involved.
Wiring:
1. Make sure all wiring complies with local codes and ordinances.
2. Be certain line voltage wiring is properly connected.
3. Refer to the oil primary control label and appliance wiring diagram for color codes.
4. After mounting, check low voltage connections to the screw terminals.
5. Strip leads 3/8” (10 mm) and insert under terminal screw.
6. Connect thermostat leads to T-T if required by installation.
Switch Settings
Figure 2 and Table 2 on the following page provide the switch settings for the units.
Switch Settings & Delays
Figure 2:
.
Switch settings for burner off-delay times
0 MIN.
0.5 MIN.
ICM1511
ICM1512
1 2
ON
2 MIN.
2 MIN.
1 2
ON
4 MIN.
4 MIN.
1 2
ON
6 MIN.
8 MIN.
1 2
ON
Burner Motor Off Delay Time:
(Shaded area is switch actuator position)
1
ENABLED
15 seconds
3
DISABLED
0 seconds
3
Valve On Delay Time:
0-15 sec.
1
• Select models may have
different timings
• Refer to device label