Diagnostics
SYMPTOMS
•
Water trough overfills
•
Water trough will not fill
WATER TROUGH OVERFILLING DURING THE FREEZE
CYCLE
Step 1
Move the 'OFF/ICE/WASH' switch to the 'OFF'
position to turn the machine off.
Step 2
If water continues to flow with the ice machine
off, disconnect power. If water continues to flow with
power disconnected verify water pressure is below 80
psig before replacing the water inlet valve. If the water
stops continue with next step.
Step 3
Check water level sensor mounting and verify
secure wiring connections at the sensor and control
board.
WATER TROUGH NOT FILLING DURING THE FREEZE
CYCLE
Step 1
Verify that the water supply is on and the
water pressure is not below 20 psig.
Step 2
Verify that the correct voltage is supplied to
the machine.
Step 3
Verify that power is being sent to the water
inlet valve.
Step 4
If the water supply and power both check out,
and no water is exiting the valve, continue to step 5
before replacing the valve.
Step 5
Check water level sensor mounting and verify
secure wiring connections at the sensor and control
board. Additionally, check if the water level sensor is in
need of cleaning.
104
Содержание IM Series
Страница 1: ...Revision Date 1 24 22 IM Series Air Water Remote Ice Machines Technician s Handbook ...
Страница 2: ......
Страница 3: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 9: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 15: ...THIS PAGE INTENTIONALLY LEFT BLANK 14 ...
Страница 17: ...How to Read a Serial Number Full Serial Number 16 ...
Страница 35: ...THIS PAGE INTENTIONALL Y LEFT BLANK 34 ...
Страница 48: ...Flexible Numeric Display FND Functions 47 ...
Страница 93: ...THIS PAGE INTENTIONALLY LEFT BLANK 92 ...
Страница 106: ...Testing the water level sensor Before S N Starting With VC 105 ...
Страница 134: ...SERVICE REMOTE RECOVERY EVACUATION CONNECTIONS 133 ...
Страница 145: ...THIS PAGE INTENTIONALLY LEFT BLANK 144 ...
Страница 154: ...IM1100 SERIES IM1100R Remote Air Cooled Model Characteristics vary depending on operating conditions CYCLE TIMES 153 ...
Страница 155: ...THIS PAGE INTENTIONALLY LEFT BLANK 154 ...
Страница 157: ...Wiring Diagram 156 ...
Страница 158: ...PCB Layout 157 ...
Страница 159: ...PCB Dip Switches 158 ...
Страница 161: ...SPACE FOR TECHNICIAN S NOTES ...
Страница 162: ...SPACE FOR TECHNICIAN S NOTES ...
Страница 163: ...SPACE FOR TECHNICIAN S NOTES ...
Страница 164: ...SPACE FOR TECHNICIAN S NOTES ...
Страница 165: ......