![background image](http://html1.mh-extra.com/html/ice/ice-1324/ice-1324_users-manual-and-installation-instructions_3353947014.webp)
•
It is the responsibility of the gas piping installer to identify the code requirement for a shut-off valve.
•
Shut-off valves, moisture trap and all associated piping must be supplied by the gas piping installer.
SET GAS PRESSURE:
Gas pressure regulator is factory set.
SET PILOT FLAME:
1. Remove all burner control knobs, and then remove the front panel.
2. The pilot adjustments are near the control valve for each set of burners.
3. Using a small, flat-blade screwdriver, turn the screw clockwise to decrease the flame size, or
counter-clockwise to increase the flame size.
4. Adjust the pilot flame to 1/4” high. Test for operation: all sections of the burner must light without
undue delay. Drafty conditions may require a higher flame to allow the pilot to remain lit.
5. Replace the front panel and all knobs before returning the unit to service.
ADJUST BURNER FLAME:
1. Remove all burner control knobs, and then remove the front panel.
2. Turn an individual burner on.
3. Loosen the locking screw on the shutter
4. Turn the shutter to admit more or less air as required. Adjust the air shutter until the flame is
mostly blue in color.
5. Tighten the locking screw when finished. Replace the front panel and all knobs before returning
the unit to service.
Figure 3
14