The grill must be installed in an area with sufficient make-up air for proper combustion, and must be
installed such that the flow of combustion and ventilation air will not be obstructed.
•
When used with an exhaust fan, special precautions must be observed to avoid interference with the
operation of the grill, such as drafts and air starvation.
GAS APPLIANCE CODE COMPLIANCE
The installation of gas piping from the outlet side of the gas meter or service regulator to the grill must be
performed by a technician qualified and certified or licensed to install gas-fired equipment.
A licensed and qualified technician must perform the initial startup and adjustment of this appliance.
The installation of this gas-fired appliance must conform to local codes, or in the absence of such codes, with
the current edition of National Fuel Gas Code ANSI Z223.1.
The installation of this gas-fired appliance must comply with applicable portions of NFPA 96 for ventilation. The
current edition of NFPA 96 (
Standard for the Installation of Equipment for the Removal
of Smoke and Grease
Laden Vapors from Commercial Cooking
Equipment
) specifies ventilation requirements to ensure the removal
of exhaust gasses and products of combustion.
IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE THAT THIS GAS GRILL INSTALLATION
CONFORMS TO ALL APPLICABLE CODES AND ORDINANCES.
The venting of this appliance must not be obstructed, nor may such venting interfere with the flow of
combustion air required for proper operation of the gas burners.
Additionally:
1. The gas supply line used to connect the grill to the gas supply system must be black iron pipe, or other
material as approved by local ordinance for gas piping.
2. Gas supply piping must be inside 3/4” diameter or greater.
3. Use pipe sealant made specifically for gas piping on all pipe joints. Apply sealant sparingly to the male
threads only. Sealant must be resistant to the action of LP gas.
4. Verify that all supply piping is clean and free of obstructions, dirt, chips and pipe sealant compound prior to
installation.
11