ICE RS26, powered by Brain OS | Gen2, v1.1217 – Content Subject to Change
44
Brain Corporation
ERROR CODES TABLE
FAULT CODE
WARNING MESSAGE
FAULT CASE
REMEDY
F1
Sit in seat
Not sitting in seat
Sit in the operator seat
F1
Sit in seat
Seat circuit open
Check circuit or contact service center
F2
EMS Active
Emergency stop
button is activated
Reset emergency stop button,
restart the machine
F2
EMS Active
Circuit open
Check circuit or contact service center
F3
Squeegee Stall
Squeegee lifting motor
is overloaded
Restart the machine
F3
Squeegee Stall
Squeegee lifting
components fault
Check squeegee lifting components
or contact service representative
if problem continues
F4
Act. Overload
Scrub head lifting
motor is overloaded
Restart the machine or
contact service center
F4
Act. Overload
Scrub head lifting
components fault
Check scrub head lifting components
or contact service center
F5
Vacuum Overload
Vacuum motor overload
Turn Off The Machine, Wait A
Moment, Restart Machine. If The Fault
Continues, Contact Service Center
F6
Brush Overload
Brush motor overload
Turn Off The Machine, Wait A
Moment, Restart Machine. If The Fault
Continues, Contact Service Center
F7
Propel Error
Propel motor overload
Turn Off The Machine, Wait A
Moment, Restart Machine. If The Fault
Continues, Contact Service Center
F8
Recovery Tank Full
Recovery tank is full
Drain the recovery tank
F8
Recovery Tank Full
Bad recovery tank
water level switch
Replace or Contact Service Center
F9
Solution Tank Empty
Solution Tank is Empty
Fill the solution tank
F9
Solution Tank Empty
Bad Solution Tank
Water Level Switch
Replace or Contact Service Center
F10
Battery Low
Battery is low, below 40%
Charge Battery
F11
Battery Very Low
Battery is low, below 20%
Charge Battery
F11
Battery Very Low
Bad Batteries
Replace Battery
F12
Brake Open
Brake Circuit Open
Contact Service Center
F13
Accel. SRO
Stepping The Propel Pedal
When Starting The Machine
Release The Propel Pedal When
Turning On The Machine
F14
Brake Short
Brake Device Overload
Restart Machine
F14
Brake Short
Bad Brake Device
Contact Service Center
F15
No Brush
No brush or brush
installed improperly
Install Brush Properly