Innovative Controls, Inc
Fire Pressure Governor User Manual
3050621, 3050622, 3050623, 3050624
Innovative Controls, Inc.
560 Braddock Avenue
East Pittsburgh, PA 15112
Page 17 of 32
Rev 1.10
The 12 Pin Key B connector is a Deutsch DT15-12PB that mates with a Deutsch DT-06-12SB plug. This
connector interfaces with the vehicle power, SAE J1939 CAN bus, IC J1939 CAN bus, warning alarm,
and intake sensor.
Table 4 12 Pin Key A Connector
Terminal
Name
Description
1A
ENGINE (+) REF
Analog Engine Control Positive Reference
2A
THROTTLE READY
Throttle Ready Interlock Input Active High
3A
HIGH IDLE
High Idle Control Input Active High
4A
OK TO PUMP
OK To Pump Interlock Input Active High
5A
DISCHARGE SENSOR GND
Discharge Sensor Ground
6A
DISCHARGE SENSOR REF
Intake 5VDC Power
7A
DISCHARGE SENSOR SIG
Intake Sensor Output Signal
8A
ENGINE SIGNAL
Analog Engine Control Signal
9A
ENGINE (-) REF
Analog Engine Control Negative Reference
10A
PUMP ENGAGED
Pump Engaged Interlock Input Active High
11A
DELAY RELAY COM (30)
Delay Relay Common Input
12A
DELAY RELAY N.O. (87)
Delay Relay Normally Open Output
Table 5 6 Pin Connector
Terminal
Name
Description
1
SYSTEM POWER
Vehicle System Power
2
SYSTEM GROUND
Vehicle System Ground
3
ALARM OUT
Alarm Output Active Low
4
SAE CAN HIGH
SAE CAN HIGH Network Signal
5
SAE CAN LOW
SAE CAN LOW Network Signal
6
SAE CAN SHEILD
SAE CAN Cable Shield
Table 6 12 Pin Key B Connector
Terminal
Name
Description
1B
SYSTEM POWER
Vehicle System Power
2B
SAE CAN HI
SAE CAN HI Network Signal
3B
SAE CAN SHIELD
SAE CAN Cable Shield
4B
IC CAN HI
Innovative Controls CAN HI Network Signal
5B
INTAKE SENSOR GND
Intake Sensor Ground
6B
INTAKE SENSOR REF
Intake 5VDC Power
7B
INTAKE SENSOR SIG
Intake Sensor Output Signal
8B
IC CAN SHIELD
Innovative Controls CAN Cable Shield
9B
IC CAN LO
Innovative Controls CAN Low Network Signal
10B
ALARM OUT
Alarm Output Active Low
11B
SAE CAN LO
SAE CAN LO Network Signal
12B
SYSTEM GROUND
Vehicle System Ground