![IC 3050621 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/ic/3050621/3050621_manual_3304629009.webp)
Innovative Controls, Inc
Fire Pressure Governor User Manual
3050621, 3050622, 3050623, 3050624
Innovative Controls, Inc.
560 Braddock Avenue
East Pittsburgh, PA 15112
Page 9 of 32
Rev 1.10
1.3.8 Transmission Temperature Indicator
The Transmission Temperature Indicator changes color to show the state of the
transmission temperature. Green indicates normal temperature, yellow when the
temperature is in the warning range, and red when the temperature is critically high. The
engine coolant temperature indicator can be configured to operate from standard J1939
diagnostic message failure mode identifiers or from user defined setpoints.
1.3.9 Battery Voltage Indicator
The Battery Voltage Indicator changes color to show the state of the vehicle system
voltage. Green indicates normal battery voltage of 12.5V or greater, yellow when the
voltage is in the warning range between 11.9 and 12.5VDC, and red when the voltage is
critically low at 11.8VDC or less. The battery voltage is measured directly at the FPG DC
power input. The battery voltage measurement has a configurable offset that can be used
to handle voltage drops between the battery and the FPG.
1.3.10 Pressure Mode Button
The Pressure button places the FPG in pressure control mode. The LED indicator is
green when the FPG is in pressure control mode. On the 3050621 and 3050622
models of the FPG, holding the pressure mode button while pressure mode is
engaged will display status messages on the status display (see 1.4.6 for a detailed
list of messages).
1.3.11 RPM Mode Button
The RPM button places the FPG in speed control mode. The LED indicator is green
when the FPG is in speed control mode. On the 3050621 and 3050622 models of the
FPG, holding the RPM mode button while RPM mode is engaged will display status
messages on the status display (see 1.4.6 for a detailed list of messages).
1.3.12 Preset Button
The Preset button is used to automatically set the pressure or speed mode setpoints
to their configured value. Preset operation in speed mode can be enabled or disabled
in the configuration menu.