General problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See the parts listing in the
Problem Determination and Service Guide
to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom
Action
A cover lock is broken, an LED
is not working, or a similar
problem has occurred.
If the part is a CRU, replace it. If the part is a FRU, the part must be replaced by a
trained service technician.
Hard disk drive problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See the parts listing in the
Problem Determination and Service Guide
to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom
Action
Not all drives are recognized by
the hard disk drive diagnostic
test.
Remove the drive that is indicated by the diagnostic tests; then, run the hard disk
drive diagnostic test again. If the remaining drives are recognized, replace the drive
that you removed with a new one. Verify that the hard disk drives have the
minimum firmware levels.
The server stops responding
during the hard disk drive
diagnostic test.
Remove the hard disk drive that was being tested when the server stopped
responding, and run the diagnostic test again. If the hard disk drive diagnostic test
runs successfully, replace the drive that you removed with a new one.
A hard disk drive was not
detected while the operating
system was being started.
Reseat all hard disk drives and cables; then, run the hard disk drive diagnostic
tests again.
A hard disk drive passes the
diagnostic SCSI Attached Disk
Test, but the problem remains.
Run the diagnostic SCSI Attached Disk Test.
Note:
This test is not available on servers using controllers other than the
integrated SAS controller or servers with IDE or SATA hard disk drives.
Chapter 6. Solving problems
41
Содержание System x3755Types 7163
Страница 2: ......
Страница 3: ...IBM System x3755 Types 8877 and 7163 Installation Guide...
Страница 34: ...22 IBM System x3755 Types 8877 and 7163 Installation Guide...
Страница 40: ...28 IBM System x3755 Types 8877 and 7163 Installation Guide...
Страница 48: ...36 IBM System x3755 Types 8877 and 7163 Installation Guide...
Страница 70: ...58 IBM System x3755 Types 8877 and 7163 Installation Guide...
Страница 82: ...70 IBM System x3755 Types 8877 and 7163 Installation Guide...
Страница 86: ...74 IBM System x3755 Types 8877 and 7163 Installation Guide...
Страница 87: ......
Страница 88: ...Part Number 49Y1730 Printed in USA 1P P N 49Y1730...