Problem
Possible
cause
Solution
Real-Time
Clock
(RTC)
loses
its
time.
The
rechargeable
battery
for
NVMEM
also
powers
the
real-time
clock.
If
this
battery
is
disconnected
for
more
than
a
few
seconds
or
the
battery
is
discharged,
the
real-time
clock
might
be
reset.
Plug
the
battery
back
in
to
the
motherboard
and
reset
the
clock
to
the
correct
time.
The
N3700
storage
system
does
not
recognize
any
of
the
installed
disk
drives.
The
1
Gb/2
Gb
switch
is
not
set
to
the
1
Gb
position.
1.
Power
off
the
N3700
storage
system.
2.
Move
the
switch
to
the
1
Gb
position.
See
Step
6
of
3.
Power
on
the
N3700
storage
system.
My
IBM
service
representative
replaced
a
CPU
module
and
now
the
new
module
can’t
see
the
disks
The
disk
ownership
mechanism
ties
disks
to
CPU
module
system
IDs.
If
your
IBM
service
representative
replaced
a
CPU
module
with
a
new
one
in,
the
disks
are
still
stamped
with
the
system
ID
of
the
old
module.
Perform
a
disk
reassign
command.
Use
the
help
command
to
get
the
exact
syntax.
I
have
unowned
disks;
why
didn’t
Data
ONTAP
use
them
to
reconstruct
a
failed
drive?
The
disks
need
to
be
“SPARES,”
not
“unowned.”
Assign
the
disks
as
spares.
The
battery
is
discharged
and
Data
ONTAP
won’t
boot.
The
battery
voltage
is
too
low
to
hold
data
for
3
days
during
a
power-out
condition.
If
you
turn
on
the
machine
and
let
it
sit
at
the
firmware
(CFE)
prompt,
it
does
not
turn
on
the
charger.
You
need
to
boot
Data
ONTAP
to
get
the
software
to
turn
on
the
battery
charger.
You
have
two
main
options
at
this
point:
1.
Leave
the
N3700
storage
system
alone
for
a
few
hours
to
let
the
battery
charge.
2.
Press
Ctrl-C
to
override
this
check.
Executing
a
priv
set
advanced
command
and
an
nv
command
shows
you
the
current
status
of
the
battery
(if
you
pressed
Ctrl-C
to
override
the
stall
condition).
You
can
also
try
out
the
environ
chassis
Battery
command
(note
that
“Battery”
is
case-sensitive).
In
either
case,
the
battery
charger
is
turned
on
and
recharges
the
battery
over
the
next
few
hours.
CFE
failed,
creating
a
POST
code.
CFE
firmware
runs
a
series
of
Power-On-Self-Tests
(POST)
before
trying
to
load
Data
ONTAP.
If
any
of
the
POSTs
fail,
a
code
is
printed.
See
for
a
description
of
the
error.
52
IBM
System
Storage
N
series:
N3700
Hardware
and
Service
Guide
Содержание System Storage N3700
Страница 1: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 2: ......
Страница 3: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 18: ...xvi IBM System Storage N series N3700 Hardware and Service Guide...
Страница 20: ...xviii IBM System Storage N series N3700 Hardware and Service Guide...
Страница 52: ...26 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 68: ...42 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 80: ...54 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 82: ...56 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 98: ...72 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 102: ...76 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 105: ......
Страница 106: ...NA 210 01254_A0 Printed in USA GA32 0515 03...