Table
17.
Environmental
EMS
messages
(continued)
Name
Parameters
Description
Corrective
action
Syslog
SNMP
monitor.cpu
Fan.failed
NOTICE
cpu_number
INT
This
message
indicates
that
a
CPU
fan
is
degraded.
The
CPU
fan
or
the
system
motherboard
might
need
to
be
replaced.
See
the
hardware
and
service
guide
that
came
with
your
system.
LOG_NOTICE:
CPU
Fan
is
stopped
#381:
CPU
Fan
is
stopped
monitor.chassis
PowerSupplies
.ok
INFO
This
message
indicates
that
all
power
supplies
are
OK.
No
corrective
action
needed.
LOG_INFO:
Chassis
power
supplies
OK
#396:
Chassis
power
supplies
OK
monitor.chassis
PowerSupply
.off
NOTICE
ps_number
INT
This
message
indicates
that
a
power
supply
is
turned
off.
Turn
the
power
supply
on.
LOG_NOTICE:
Chassis
power
supply
off
#395:
Chassis
power
supply
is
off
monitor.chassis
PowerSupply
.
notPresent
NOTICE
ps_number
INT
This
message
indicates
that
a
power
supply
is
not
present.
Add
a
power
supply
to
the
N3700
storage
system.
LOG_NOTICE:
Chassis
power
supply
not
present
#394:
Chassis
power
supply
is
not
present
monitor.chassis
PowerSupply
.
degraded
NOTICE
ps_number
reasonText
INT
STRING
This
message
indicates
that
a
power
supply
is
degraded.
A
replacement
power
supply
might
be
required.
Contact
IBM
technical
support
for
further
instruction.
LOG_NOTICE:
Chassis
power
supply
is
degraded
#392:
Chassis
power
supply
is
degraded
monitor.chassis
Power.ok
NOTICE
This
messages
indicates
that
the
motherboard
power
is
OK.
No
corrective
action
needed.
LOG_NOTICE:
Chassis
power
is
OK
#406:
Chassis
power
is
OK
monitor.chassis
Power.degraded
NOTICE
reasonText
STRING
This
message
indicates
that
a
power
supply
is
degraded.
Replace
the
power
supplies.
1
LOG_NOTICE:
Chassis
power
is
degraded
#403:
Chassis
power
is
degraded
1
Degraded
power
might
be
caused
by
bad
power
supplies,
bad
wall
power,
or
bad
components
on
the
motherboard.
If
spare
power
supplies
are
available,
try
replacing
them
to
see
whether
that
alleviates
the
problem.
Otherwise,
contact
IBM
technical
support
for
further
instruction.
Chapter
6.
Error
messages
and
troubleshooting
49
Содержание System Storage N3700
Страница 1: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 2: ......
Страница 3: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 18: ...xvi IBM System Storage N series N3700 Hardware and Service Guide...
Страница 20: ...xviii IBM System Storage N series N3700 Hardware and Service Guide...
Страница 52: ...26 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 68: ...42 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 80: ...54 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 82: ...56 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 98: ...72 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 102: ...76 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 105: ......
Страница 106: ...NA 210 01254_A0 Printed in USA GA32 0515 03...