Attention:
Depending
on
the
design
of
your
N3700
CPU
module,
direct
connections
to
expansion
units
must
be
made
with
either
Fibre
Channel
copper
cables
or
Fibre
Channel
optical
cables,
as
described
in
the
following
bullets:
v
For
direct
connections
to
N3700
early
CPU
module
designs:
Use
NAS-to-EXP
Fibre
Channel
copper
cables
(FC
#2020
or
2022).
For
attachment
to
an
N3700
Model
A10,
one
NAS-to-EXP
Fibre
Channel
copper
cable
is
required.
For
attachment
to
an
N3700
Model
A20,
two
NAS-to-EXP
Fibre
Channel
copper
cables
are
required.
v
For
direct
connections
to
N3700
current
CPU
module
designs:
Use
an
LC-to-LC
Fibre
Channel
optical
cable
and
two
SFPs
for
attachment
to
an
N3700
Model
A10.
Use
two
LC-to-LC
Fibre
Channel
optical
cables
and
four
SFPs
for
attachment
to
an
N3700
Model
A20.
Required
manuals,
tools
and
equipment
You
need
the
following
manuals:
v
Installation
and
Setup
Instructions
for
your
N3700
storage
system
v
IBM
System
Storage
N
series
Data
ONTAP
Software
Setup
Guide
for
your
version
of
Data
ONTAP,
if
applicable
v
IBM
System
Storage
N
series
Data
ONTAP
Cluster
Installation
and
Administration
Guide
or
IBM
System
Storage
N
series
Data
ONTAP
Active-Active
Configuration
Guide
for
your
version
of
Data
ONTAP,
if
applicable
You
need
to
supply
the
following
tools
and
equipment:
v
Ethernet
LAN
cables
v
Fibre
Channel
cables
v
Console
(for
example,
a
PC
or
laptop)
and
a
serial
null
modem
cable
v
#2
Phillips
screwdriver
v
Pointed
tool
for
setting
termination
switches
v
7-mm
nut
driver
v
Grounding
leash
and
ESD
strap
Note:
To
verify
your
shipping
contents,
see
the
IBM
System
Storage
N3700
Installation
and
Setup
Instructions
.
Handling
static-sensitive
devices
CAUTION:
The
N3700
uses
electronic
components
that
are
sensitive
to
static
electricity.
Static
discharge
from
your
clothing
or
other
fixtures
around
you
can
damage
these
components.
Put
on
an
antistatic
ESD
strap
and
grounding
leash
to
free
yourself
of
static
electricity
before
touching
any
electronic
components.
C
B
A
Te rm
On
Off
B
Example: No additional disk shelves
Figure
2.
Port
labeling
for
current
N3700
CPU
module
designs
2
IBM
System
Storage
N
series:
N3700
Hardware
and
Service
Guide
Содержание System Storage N3700
Страница 1: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 2: ......
Страница 3: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 18: ...xvi IBM System Storage N series N3700 Hardware and Service Guide...
Страница 20: ...xviii IBM System Storage N series N3700 Hardware and Service Guide...
Страница 52: ...26 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 68: ...42 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 80: ...54 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 82: ...56 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 98: ...72 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 102: ...76 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 105: ......
Страница 106: ...NA 210 01254_A0 Printed in USA GA32 0515 03...