Configuring
for
initiator
mode
To
configure
the
N3700
storage
system
for
initiator
mode,
complete
the
following
steps.
1.
Remove
the
FCP
license
by
entering
the
following
command:
license
delete
fcp
Example:
n3700a>
license
delete
fcp
Fri
Dec
5
14:59:02
EST
[n3700a:
fcp.service.shutdown:info]:
FCP
service
shutdown
cf.takeover.on_panic
is
changed
to
off
A
reboot
is
required
for
TapeSAN
service
to
become
available.
unlicensed
fcp.
FCP
disabled.
n3700a>
Fri
Dec
5
14:59:02
EST
[n3700a:
rc:notice]:
fcp
unlicensed
2.
Reboot
the
system
by
entering
the
following
command:
reboot
3.
After
the
reboot,
verify
that
port
C
is
in
initiator
mode
by
entering
the
following
command:
sysconfig
Example:
n3700a>
sysconfig
NetApp
Release
xxx:
Mon
Aug
25
02:20:04
PDT
2003
System
ID:
0084165669
(n3700a);
partner
ID:
0084165671
(n3700b)
System
Serial
Number:
379589
(n3700a)
slot
0:
System
Board
Processors:
2
Processor
revision:
B2
Processor
type:
1250
Memory
Size:
1022
MB
slot
0:
FC
Host
Adapter
0b
14
Disks:
952.0GB
1
shelf
with
EFH
slot
0:
FC
Host
Adapter
0c
slot
0:
SB1250-Gigabit
Dual
Ethernet
Controller
e0a
MAC
Address:
00:a0:98:00:d5:90
(100tx-fd-up)
e0b
MAC
Address:
00:a0:98:00:d5:91
(auto-unknown-cfg_down)
slot
0:
NetApp
ATA/IDE
Adapter
0a
(0x00000000000001f0)
0a.0
122MB
Note:
In
the
above
example,
Fibre
Channel
port
C
is
identified
as
FC
Host
Adapter
0c
.
4.
Enable
port
C
by
entering
the
following
command.
storage
enable
adapter
0c
Example:
n3700a>
storage
enable
adapter
0c
Mon
Dec
8
08:55:09
GMT
[rc:notice]:
Onlining
Fibre
Channel
adapter
0c.
host
adapter
0c
enable
succeeded
For
more
information
about
configuring
your
SAN,
see
the
IBM
System
Storage
N
series
Data
ONTAP
Block
Access
Management
Guide
for
your
version
of
Data
ONTAP.
18
IBM
System
Storage
N
series:
N3700
Hardware
and
Service
Guide
Содержание System Storage N3700
Страница 1: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 2: ......
Страница 3: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 18: ...xvi IBM System Storage N series N3700 Hardware and Service Guide...
Страница 20: ...xviii IBM System Storage N series N3700 Hardware and Service Guide...
Страница 52: ...26 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 68: ...42 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 80: ...54 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 82: ...56 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 98: ...72 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 102: ...76 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 105: ......
Страница 106: ...NA 210 01254_A0 Printed in USA GA32 0515 03...