Table
17.
Environmental
EMS
messages
(continued)
Name
Parameters
Description
Corrective
action
Syslog
SNMP
monitor.chassis
Fan.removed
ALERT
fan_name
STRING
This
is
a
warning
message
that
is
issued
when
a
chassis
fan
is
removed.
The
fan
unit
should
be
replaced.
LOG_ALERT:
Chassis
FRU
is
removed
#363:
Chassis
FRU
is
removed
monitor.chassis
Temperature.ok
NOTICE
This
message
is
issued
when
the
chassis
temperature
is
normal.
No
corrective
action
needed.
LOG_NOTICE:
Chassis
temperature
is
ok
#376:
Chassis
temperature
is
ok
monitor.chassis
Temperature
.warm
ALERT
describe_
toowarm
STRING
This
is
a
warning
message
that
is
issued
when
the
chassis
temperature
is
too
warm.
Check
to
see
if
air
conditioning
units
are
needed,
or
whether
they
are
functioning
properly.
LOG_ALERT:
Chassis
temperature
is
too
warm
#372:
Chassis
temperature
is
too
warm
monitor.chassis
Temperature
.cool
ALERT
describe_
toocool
STRING
This
is
a
warning
message
that
is
issued
when
the
chassis
temperature
is
too
cool.
Raise
the
ambient
temperature
around
the
N3700
storage
system.
LOG_ALERT:
Chassis
temperature
is
too
cool
#372:
Chassis
temperature
is
too
cool
monitor.shut
down.chassis
OverTemp
CRIT
describe_
toohot
STRING
This
message
is
issued
just
before
shutdown,
indicating
the
chassis
temperature
is
too
hot.
Check
to
see
if
air
conditioning
units
are
needed,
or
whether
they
are
functioning
properly.
LOG_CRIT:
Chassis
temperature
is
too
hot
#371:
Chassis
temperature
is
too
hot
monitor.shut
down.chassis
UnderTemp
CRIT
describe_
toocold
STRING
This
message
is
issued
just
before
shutdown
when
the
chassis
temperature
becomes
too
cold.
Raise
the
ambient
temperature
around
the
N3700
storage
system.
LOG_CRIT:
Chassis
temperature
is
too
cold
#371:
Chassis
temperature
is
too
cold
monitor.cpu
Fan.ok
INFO
cpu_number
INT
This
message
indicates
that
a
CPU
fan
is
OK.
No
corrective
action
needed.
LOG_INFO:
CPU
Fan
OK
#386:
CPU
Fan
OK
monitor.cpu
Fan.degraded
NOTICE
cpu_number
INT
This
message
indicates
that
a
CPU
fan
is
degraded.
The
CPU
fan
or
the
system
motherboard
might
need
to
be
replaced.
See
the
hardware
and
service
guide
that
came
with
your
system.
LOG_NOTICE:
CPU
Fan
is
slow
#383:
CPU
Fan
is
slow
48
IBM
System
Storage
N
series:
N3700
Hardware
and
Service
Guide
Содержание System Storage N3700
Страница 1: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 2: ......
Страница 3: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 18: ...xvi IBM System Storage N series N3700 Hardware and Service Guide...
Страница 20: ...xviii IBM System Storage N series N3700 Hardware and Service Guide...
Страница 52: ...26 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 68: ...42 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 80: ...54 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 82: ...56 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 98: ...72 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 102: ...76 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 105: ......
Страница 106: ...NA 210 01254_A0 Printed in USA GA32 0515 03...