Rack
safety
Rack
installation
DANGER
v
Always
lower
the
leveling
pads
on
the
rack
cabinet.
v
Always
install
stabilizer
brackets
on
the
rack
cabinet.
v
To
avoid
hazardous
conditions
due
to
uneven
mechanical
loading,
always
install
the
heaviest
devices
in
the
bottom
of
the
rack
cabinet.
Always
install
servers
and
optional
devices
starting
from
the
bottom
of
the
rack
cabinets.
v
Rack-mounted
devices
are
not
to
be
used
as
a
shelf
or
work
space.
Do
not
place
any
object
on
top
of
rack-mounted
devices.
v
Each
rack
cabinet
might
have
more
than
one
power
cord.
Be
sure
to
disconnect
all
power
cords
in
the
rack
cabinet
before
servicing
any
device
in
the
rack
cabinet.
v
Connect
all
devices
installed
in
a
rack
cabinet
to
power
devices
installed
in
the
same
rack
cabinet.
Do
not
plug
a
power
cord
from
a
device
installed
in
one
rack
cabinet
into
a
power
device
installed
in
a
different
rack
cabinet.
CAUTION:
v
Do
not
install
a
unit
in
a
rack
where
the
internal
rack
ambient
temperatures
will
exceed
the
manufacturer’s
recommended
ambient
temperature
for
all
your
rack-mounted
devices.
v
Do
not
install
a
unit
in
a
rack
where
the
air
flow
is
compromised.
Ensure
that
air
flow
is
not
blocked
or
reduced
on
any
side,
front,
or
back
of
a
unit
used
for
air
flow
through
the
unit.
v
Consideration
should
be
given
to
the
connection
of
the
equipment
to
the
supply
circuit
so
that
overloading
of
the
circuits
does
not
compromise
the
supply
wiring
or
overcurrent
protection.
v
To
provide
the
correct
power
connection
to
a
rack,
refer
to
the
rating
labels
located
on
the
equipment
in
the
rack
to
determine
the
total
power
requirement
of
the
supply
circuit.
v
This
drawer
is
a
fixed
drawer
and
should
not
be
moved
for
servicing
unless
specified
by
manufacturer.
Attempting
to
move
the
drawer
partially
or
completely
out
of
the
rack
may
cause
the
rack
to
become
unstable
or
cause
the
drawer
to
fall
out
of
the
rack.
Safety
and
environmental
notices
vii
Содержание System Storage N3700
Страница 1: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 2: ......
Страница 3: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 18: ...xvi IBM System Storage N series N3700 Hardware and Service Guide...
Страница 20: ...xviii IBM System Storage N series N3700 Hardware and Service Guide...
Страница 52: ...26 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 68: ...42 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 80: ...54 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 82: ...56 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 98: ...72 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 102: ...76 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 105: ......
Страница 106: ...NA 210 01254_A0 Printed in USA GA32 0515 03...