Follow these steps to install the QSFPs and cables in the 16 Gbps core blades.
These transceivers and cables are used to form the inter-chassis links (ICL) with
neighboring SAN384B-2 and SAN768B-2 backbones. The transceivers should be
installed in the blades before connecting the cables. Because each QSFP contains
four 16 Gbps ports, be aware that any problems with one port could affect all four
ports in the quad if the QSFP has to be replaced.
1.
Position one of the QSFP transceivers so that the key is oriented correctly to the
port. Insert the transceiver into the port until it is firmly seated. Transceivers
are keyed so that they can only be inserted with the correct orientation. If a
transceiver does not slide in easily, ensure that it is correctly oriented. When
the transceiver is correctly seated, the status LED will flash amber several times
and then turn solid amber.
2.
Remove the protective cap from the special QSFP cable and insert it into the
transceiver until it is firmly seated. The cables are also keyed to fit into the
transceivers correctly. When the cable is correctly seated, the status LED will
change from amber to green.
3.
Repeat steps 1 and 2 for the remaining ICLs.
4.
Organize the cables (see “Managing cables” on page 44).
5.
Verify the chassis and connector and port status using the
switchShow -qsfp
command. A sample of the command output is shown below. The example is
from a SAN384B-2 with a core blade installed in slot 3. Note that the state
reported for an unconnected QSFP (shown QSFP 0 and Ports 0-3 below) is
No_SigDet. This is different from the State of No_Synch that is reported for
regular SFPs that are unconnected. QSFP 7 (ports 3/28-3/31, Index 748-751) in
the following example shows the results for a connected QSFP.
switch:FID128:admin>
switchshow -qsfp
switchName: switch_name
switchType: 121.3
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 75
switchId: fffc4b
switchWwn: 10:00:00:05:1e:4f:eb:00
zoning: ON (zoning_name)
switchBeacon: OFF
FC Router: OFF
Allow XISL Use: OFF
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Address Mode
0]
Index Slot Port QSFP Address Media Speed
State
Proto
=============================================================
256
3
0
0
------
id
16G
No_SigDet
FC
257
3
1
0
------
id
16G
No_SigDet
FC
258
3
2
0
------
id
16G
No_SigDet
FC
259
3
3
0
------
id
16G
No_SigDet
FC
260
3
4
1
------
--
16G
No_Module
FC
261
3
5
1
------
--
16G
No_Module
FC
262
3
6
1
------
--
16G
No_Module
FC
263
3
7
1
------
--
16G
No_Module
FC
264
3
8
2
------
--
16G
No_Module
FC
265
3
9
2
------
--
16G
No_Module
FC
266
3
10
2
------
--
16G
No_Module
FC
267
3
11
2
------
--
16G
No_Module
FC
268
3
12
3
------
--
16G
No_Module
FC
269
3
13
3
------
--
16G
No_Module
FC
270
3
14
3
------
--
16G
No_Module
FC
271
3
15
3
------
--
16G
No_Module
FC
736
3
16
4
------
--
16G
No_Module
FC
737
3
17
4
------
--
16G
No_Module
FC
Chapter 3. Starting and configuring the SAN384B-2
43
|
Содержание SAN384B-2
Страница 2: ......
Страница 8: ...vi SAN384B 2 Installation Service and User Guide ...
Страница 12: ...x SAN384B 2 Installation Service and User Guide ...
Страница 14: ...xii SAN384B 2 Installation Service and User Guide ...
Страница 16: ...xiv SAN384B 2 Installation Service and User Guide ...
Страница 28: ...xxvi SAN384B 2 Installation Service and User Guide ...
Страница 32: ...xxx SAN384B 2 Installation Service and User Guide ...
Страница 82: ...50 SAN384B 2 Installation Service and User Guide ...
Страница 146: ...114 SAN384B 2 Installation Service and User Guide ...
Страница 172: ...140 SAN384B 2 Installation Service and User Guide ...
Страница 182: ...Taiwan Class A Electronic Emission Statement 150 SAN384B 2 Installation Service and User Guide ...
Страница 187: ...WWN bezel 65 card status 65 WWN bezel installing 88 removing 88 WWN card failure 65 removing 88 Index 155 ...
Страница 188: ...156 SAN384B 2 Installation Service and User Guide ...
Страница 189: ......
Страница 190: ... Part Number 98Y2654 Printed in USA GA32 0894 03 1P P N 98Y2654 ...