Verifying operation of the new CP blade
To verify that boot and POST are complete on the new CP blade and that the CP
blade has achieved failover redundancy, complete the following steps.
1.
Enter
slotShow
. The command output shows the new CP blade as “enabled.”
If the standby CP is unresponsive, try unplugging the new CP blade, running
haDisable
on the active CP blade, and plugging the new CP blade back in. At
that point, you can repeat step 1 to begin the verification process again.
2.
Determine the Fabric OS version by entering
firmwareShow
. If the serial
console on the replacement CP blade is connected, issue the
firmwareShow
command there. More information is available through the console.
Attention:
The SAN384B-2 requires Fabric OS 7.0.0 or later, to be recognized.
The FC8-32E and FC8-48E blades require FOS 7.0.1 or later. If the firmware on
the replacement blade is earlier than 7.0.0, it must be brought up to the version
(7.0.0 or later) on the active CP blade, which must be at least 7.0.0. IBM
recommends upgrading to the latest version available.
3.
If the firmware versions for both CP blades are the same, skip to “Completing
the CP8 blade replacement” on page 81.
If the firmware version on the replacement blade does not match that on the
active CP blade, a warning message appears with the results of the
firmwareShow
command. The results of the
firmwareShow
command may
look similar to the following. Note the warning message at the end of the
output.
SAN384B-2_120:admin>
firmwareshow
Slot Name
Appl
Primary/Secondary Versions
Status
-------------------------------------------------------------
4 CP0
FOS
v7.0.0a
ACTIVE
v7.0.0a
5 CP1
FOS
v7.0.0
STANDBY *
v7.0.0
WARNING: The local CP and remote CP have different versions
of firmware, please retry firmwaredownload command.
4.
You must bring the replacement blade to the same firmware level as the active
blade by using the
firmwareDownload -s
command
directly on the replacement
blade
to bring it up to the proper level. The
firmwareshow
command results
show which slots hold the active and standby (replacement) CP blades.
If you are using an FTP server to download the firmware, skip to
“Downloading firmware from an FTP server.” If you are using a USB device to
download the firmware, skip to “Downloading firmware from a USB device”
on page 80.
If the firmware on the standby CP blade is more than one level down from the
level on the active CP blade, you must have formatted USB devices for each of
the versions you will need to upgrade.
Table 14. Steps for upgrading through multiple versions of Fabric OS
If your current Fabric OS
version is...
and your target FOS version
is...
complete these upgrade
steps
7.0.0x
7.0.1
use
firmwareDownload -s
to
upgrade directly to 7.0.1
Downloading firmware from an FTP server
For this task, refer to Table 14 for the correct sequence of upgrading firmware
versions to reach your target version. Complete the following steps to download
the firmware from an FTP server.
78
SAN384B-2 Installation, Service, and User Guide
|
|
|
|
Содержание SAN384B-2
Страница 2: ......
Страница 8: ...vi SAN384B 2 Installation Service and User Guide ...
Страница 12: ...x SAN384B 2 Installation Service and User Guide ...
Страница 14: ...xii SAN384B 2 Installation Service and User Guide ...
Страница 16: ...xiv SAN384B 2 Installation Service and User Guide ...
Страница 28: ...xxvi SAN384B 2 Installation Service and User Guide ...
Страница 32: ...xxx SAN384B 2 Installation Service and User Guide ...
Страница 82: ...50 SAN384B 2 Installation Service and User Guide ...
Страница 146: ...114 SAN384B 2 Installation Service and User Guide ...
Страница 172: ...140 SAN384B 2 Installation Service and User Guide ...
Страница 182: ...Taiwan Class A Electronic Emission Statement 150 SAN384B 2 Installation Service and User Guide ...
Страница 187: ...WWN bezel 65 card status 65 WWN bezel installing 88 removing 88 WWN card failure 65 removing 88 Index 155 ...
Страница 188: ...156 SAN384B 2 Installation Service and User Guide ...
Страница 189: ......
Страница 190: ... Part Number 98Y2654 Printed in USA GA32 0894 03 1P P N 98Y2654 ...