The redundant ac-power switch comes with two IEC 320-C19 to C14 power cables
to connect to rack PDUs. There are no country-specific cables for the redundant
ac-power switch.
The power cable between the redundant ac-power switch and the 2145 UPS-1U is
rated at 10 A.
Redundant ac-power switch specifications
The following tables list the physical characteristics of the redundant ac-power
switch.
Dimensions and weight
Ensure that space is available in a rack that is capable of supporting the redundant
ac-power switch.
Height
Width
Depth
Maximum weight
43 mm (1.69 in.)
192 mm (7.56 in.)
240 mm
2.6 kg (5.72 lb)
Additional space requirements
Ensure that space is also available in the rack for the side mounting plates on
either side of the redundant ac-power switch.
Location
Width
Reason
Left side
124 mm (4.89 in.)
Side mounting plate
Right side
124 mm (4.89 in.)
Side mounting plate
Heat output (maximum)
The maximum heat output that is dissipated inside the redundant ac-power switch
is approximately 20 watts (70 Btu per hour).
Uninterruptible power-supply environment requirements
An uninterruptible power-supply environment requires that certain specifications
for the physical site of the SAN Volume Controller must be met.
2145 UPS-1U environment
All SAN Volume Controller models are supported with the 2145 UPS-1U.
2145 UPS-1U specifications
The following tables describe the physical characteristics of the 2145 UPS-1U.
2145 UPS-1U dimensions and weight
Ensure that space is available in a rack that is capable of supporting the 2145
UPS-1U.
50
SAN Volume Controller: Model 2145-CG8 Hardware Installation Guide
Содержание SAN Volume Controller 2145-CG8
Страница 6: ...vi SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 8: ...viii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 28: ...xxviii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 34: ...6 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 72: ...44 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 99: ...Russia Electromagnetic Interference EMI Class A Statement Taiwan Class A compliance statement rusemi Notices 71...
Страница 100: ...72 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 102: ...74 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 104: ...76 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 109: ......