- Part number 31P1294: Kit containing the power and signal cable bundle,
quantity 1
– The support rail kit contains a number of components within its box.
Verify that you have the following items:
- One left side rail
- One right side rail
- Four M6 screws in a plastic ziplock bag
v
Feature codes 9714, 9715, 9716, 9717, 9718, 9719, 9720, 9721, 9722, 9723, 9724,
9725, 9726, and 9727 each ship a single power cable. Use the power plug that
is appropriate to your location unless you are connecting to a rack-mounted
power distribution unit.
v
Optional feature code 5608 ships uninstalled, quantity 1 - 4
v
Optional feature code 4500 ships installed in the SAN Volume Controller
2145-CG8 node, quantity 1
v
Optional feature code 4601 ships installed in the SAN Volume Controller
2145-CG8 node, quantity 1 - 4
v
Optional feature codes 5700 and 5711 ship installed in the SAN Volume
Controller 2145-CG8 node, quantity 1 each
v
Feature code 8115 ships in a separate box that is labeled part number
31P1391. Verify that the box contains these items:
– 2145 UPS-1U, quantity 1
– 2145 UPS-1U output power-cable retention-bracket kit, quantity 1
– Cable clip and two screws in plastic ziplock bag
– Uninterruptible power-supply rail kit, quantity 1
– Power cable for connecting the uninterruptible power supply to a rack;
PDU, quantity 1
– Multilingual battery-reconnection flyer and other miscellaneous flyers
– Environmental Notices and User's Guide CD
v
Optional feature code 8300 ships in a box within the main box. Verify that
the box contains the following items:
– Part number 95P5083: redundant ac-power switch, quantity 1
– Part number 31P0966: power cables, quantity 2
– Part number 96P1728: mounting plates, quantity 2
– Part number 12J5289: hex head screws, quantity 4
– Part number 00N8709: “c” clips, quantity 4
– Part number 24R0207: other screws, quantity 6
– Part number 31P0876: label set, quantity 1
If feature codes 5305 or 5325 are not ordered for Fibre Channel connection, the
customer must supply their own fiber-optic Fibre Channel cables. Make sure
that four cables per node are available.
If feature codes 5700 and 5711 are ordered, and feature codes 5305 and 5325 are
not ordered for Ethernet connection, the customer must supply their own OM2
or OM3 fiber-optic cables. Make sure that two cables per node are available.
Note:
Part numbers are subject to change between SAN Volume Controller
releases. The part numbers listed here might not always reflect what the
customer has received.
4.
Read “Safety and environmental notices” on page ix to ensure that you are
correctly installing the 2145 UPS-1U units.
Chapter 2. Installing the SAN Volume Controller 2145-CG8 hardware
11
Содержание SAN Volume Controller 2145-CG8
Страница 6: ...vi SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 8: ...viii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 28: ...xxviii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 34: ...6 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 72: ...44 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 99: ...Russia Electromagnetic Interference EMI Class A Statement Taiwan Class A compliance statement rusemi Notices 71...
Страница 100: ...72 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 102: ...74 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 104: ...76 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 109: ......
Страница 110: ...Part Number 31P1669 Printed in USA GC27 3923 02 1P P N 31P1669...