c.
Ensure that the insulation is not worn or damaged.
4.
Check for any obvious nonstandard changes, both inside and outside the unit.
Use good judgment about the safety of any such changes.
5.
Check inside SAN Volume Controller for any obvious unsafe conditions, such
as metal particles, contamination, water or other fluids, or marks of
overheating, fire, or smoke damage.
6.
Check for worn, damaged, or pinched cables.
7.
Ensure that the voltage that is specified on the product-information label
matches the specified voltage of the electrical power outlet. If necessary, verify
the voltage.
8.
Inspect the power-supply assemblies and check that the fasteners (screws or
rivets) in the cover of the power-supply unit have not been removed or
disturbed.
9.
Before connecting SAN Volume Controller to the storage area network (SAN),
check the grounding.
External device check
Ensure that you perform an external device check before you install or service the
SAN Volume Controller.
About this task
To conduct an external device check, perform the following steps:
Procedure
1.
Verify that all external covers are present and are not damaged.
2.
Ensure that all latches and hinges are in the correct operating condition.
3.
If SAN Volume Controller is not installed in a rack cabinet, check for loose or
broken feet.
4.
Check the power cord for damage.
5.
Check the external signal cable for damage.
6.
Check the cover for sharp edges, damage, or alterations that expose the internal
parts of the device.
7.
Check the bottom of the external cover for any loose or broken feet.
8.
Correct any problems that you find.
Internal device checks
Ensure that you perform an internal device check before you install or service SAN
Volume Controller.
About this task
To conduct the internal device check, perform the following steps:
Procedure
1.
Check for any non-IBM changes that might have been made to the device. If
any are present, obtain the “Non-IBM Alteration Attachment Survey,” form
number R009, from the IBM branch office. Complete the form and return it to
the branch office.
2.
Check the condition of the inside of the device for any metal or other
contaminants, or any indications of water, other fluid, fire, or smoke damage.
xiv
SAN Volume Controller: Model 2145-CG8 Hardware Installation Guide
Содержание SAN Volume Controller 2145-CG8
Страница 6: ...vi SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 8: ...viii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 28: ...xxviii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 34: ...6 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 72: ...44 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 99: ...Russia Electromagnetic Interference EMI Class A Statement Taiwan Class A compliance statement rusemi Notices 71...
Страница 100: ...72 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 102: ...74 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 104: ...76 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 109: ......
Страница 110: ...Part Number 31P1669 Printed in USA GC27 3923 02 1P P N 31P1669...