9
2145 UPS-1U cable-retention bracket
10
SAN Volume Controller cable-retention brackets
11
2145 UPS-1U mounting brackets
Not shown in Figure 3 on page 8 are two 2145 UPS-1U input-power cables that are
provided. One cable comes with the 2145 UPS-1U; it has an IEC 320-C14 plug,
which is suitable for most rack-mounted power distribution units. The other
country-specific cable comes with the SAN Volume Controller node; this cable is
intended for your country-specific power sockets. Use only one of these cables.
Before you start the installation, verify that all the parts that were ordered have
been received and that all the component assemblies are complete. Verify that you
know the quantity of nodes and optional features that were ordered.
Three boxes are shipped for each node: one box contains the uninterruptible power
supply, one box contains the publications, and the third box contains all the other
parts. A label on the third, or main, box indicates the features that were shipped.
Note:
1.
You must install at least two SAN Volume Controller nodes. Each node requires
an uninterruptible power supply.
2.
Optionally, install two redundant ac-power switches to power the nodes in an
I/O group through two 2145 UPS-1U units.
3.
You must ensure that you have the appropriate cables to connect the redundant
ac-power switch or uninterruptible power supply to the power distribution
unit. See Appendix B, “SAN Volume Controller physical installation planning,”
on page 47 for more details.
About this task
Perform the following steps to prepare for installation:
Procedure
1.
Ensure that you have everything you need for installation, including the
customer-completed planning tables and charts. The customer can obtain the
planning tables and charts from www.ibm.com/storage/support/2145.
The SAN Volume Controller planning information provides guidelines for
completing the planning tables and charts. These tables include the location of
hardware, cable connection, and configuration data information that you need
to complete the installation procedures. If you are connecting cables to switches
that are currently in use, confirm with the customer that it is safe for you to
proceed. Go no further with these instructions until you are satisfied that all
the information is correct and valid.
2.
The label on the main box indicates features that were shipped. Make sure that
the contents and quantity match the order.
The following feature codes are included:
v
Feature code 0010: initial SAN Volume Controller 2145-CG8 software
preinstalled on feature code 3001 and 3002
v
One of the following:
– Feature code 3001: initial SAN Volume Controller 2145-CG8 node, quantity
1
– Feature code 3002: additional SAN Volume Controller 2145-CG8 node,
quantity 1
Chapter 2. Installing the SAN Volume Controller 2145-CG8 hardware
9
Содержание SAN Volume Controller 2145-CG8
Страница 6: ...vi SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 8: ...viii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 28: ...xxviii SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 34: ...6 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 72: ...44 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 99: ...Russia Electromagnetic Interference EMI Class A Statement Taiwan Class A compliance statement rusemi Notices 71...
Страница 100: ...72 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 102: ...74 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 104: ...76 SAN Volume Controller Model 2145 CG8 Hardware Installation Guide...
Страница 109: ......
Страница 110: ...Part Number 31P1669 Printed in USA GC27 3923 02 1P P N 31P1669...