Procedure
1.
Prepare the system for operation. For instructions, see “Preparing the 8335-GTB system for operation
after you remove and replace internal parts” on page 198.
2.
Verify that the jumper is set to air-cooled by using the
ipmitool
command:
ipmitool -I lanplus -U <username> -P <password> -H <bmc ip or hostname> sensor list | grep "Water Cooled"
The value for the air-cooled jumper setting is
0x0080
for the
Water Cooled
status:
Water Cooled | 0x0 | discrete | 0x0080| na | na | na | na | na | na
If the value returned is
0x0180
, which indicates a water-cooled setting, you must correct the jumper
setting as shown in “Replacing the system backplane in an air-cooled 8335-GTB” on page 100.
3.
Set the system serial number in the system backplane.
After you replace the system backplane, you must set the system serial number in the system
backplane by using the vital product data (VPD) update tool. To download the tool, complete the
following steps:
a.
Go to the IBM Support Portal website(www.ibm.com/support/entry/portal/product/power/
scale-out_lc).
b.
In the search field, enter your machine type and model. Then, click the correct product support
entry for your system.
c.
From the Downloads list, click Scale-out LC system VPD update tool.
d.
Follow the directions that are provided with the tool to update the VPD.
4.
Restore the BMC network settings by completing the following steps:
a.
Access the BMC GUI from a browser. The user needs Administrator privilege. You can use either
Google Chrome or Mozilla Firefox browsers.
b.
Navigate to HMC Management > Console Settings > Change BMC/IPMI Network Settings
c.
Set the following values:
IP address
Subnet mask
Gateway
5.
Update the BMC firmware.
After you replace a system backplane, you must update the BMC firmware. To download the update,
go to the Fix Central website (www.ibm.com/support/fixcentral/). Follow the instructions provided
with the update.
Removing and replacing the system backplane in a water-cooled
8335-GTB
Learn how to remove the system backplane in the water-cooled IBM Power System S822LC (8335-GTB)
system.
Preparing to remove the system backplane from a water-cooled 8335-GTB
To prepare the water-cooled system to remove a system backplane, complete the steps in this procedure.
Before you begin
Before you begin replacing the system backplane, record the system serial number and machine model
type. After you replace the system backplane, you must set the system serial number and machine model
type into the replacement system backplane.
After you replace the system backplane, you must set the system serial number in the system backplane
by using the vital product data (VPD) update tool. To download the tool, complete the following steps:
Removing and replacing parts in the IBM Power System S822LC (8335-GTB)
121
Содержание S822LC
Страница 1: ...Power Systems Servicing the IBM Power System S822LC 8335 GTB IBM ...
Страница 2: ......
Страница 3: ...Power Systems Servicing the IBM Power System S822LC 8335 GTB IBM ...
Страница 16: ...xiv Power Systems Servicing the IBM Power System S822LC 8335 GTB ...
Страница 204: ...188 Power Systems Servicing the IBM Power System S822LC 8335 GTB ...
Страница 242: ...226 Power Systems Servicing the IBM Power System S822LC 8335 GTB ...
Страница 243: ......
Страница 244: ...IBM ...