3-1 (Page 17 of 24). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
2BA00337
Service Processor reports Memory
Critical Over Temperature Slow
Shutdown request.
1. Check for cool air flow obstructions
to the system.
2. Check fans for obstructions that
prevent them from normal
operation (example: a cable caught
in the fan preventing it from
spinning)
3. If problem persists, replace
Memory Card.
2BA00338
Service Processor reports Generic Fast
Shutdown request.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00340
Service Processor reports Locked fan -
Fast Shutdown request fan number 1.
1. Replace fan 1.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
2BA00341
Service Processor reports Locked fan -
Fast Shutdown request fan number 2.
1. Replace fan 2.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
2BA00342
Service Processor reports Locked fan -
Fast Shutdown request fan number 3.
1. Replace fan 3.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
2BA00343
Service Processor reports Locked fan -
Fast Shutdown request fan number 4.
1. Replace fan 4.
2. If problem persi.ts, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
2BA00350
Service Processor reports Generic
Immediate Shutdown request.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00351
Service Processor reports Generic AC
power loss EPOW.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00352
Service Processor reports Loss of AC
power (outlet).
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00353
Service Processor reports Loss of AC
power (power button).
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
3-18
Service Guide
Содержание RS6000 - 7026 - H70
Страница 1: ...RS 6000 7025 F50 Series IBM Service Guide SA38 0541 01...
Страница 6: ...vi Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 18: ...Rear View 1 2 Service Guide...
Страница 23: ...Operator Panel Chapter 1 Reference Information 1 7...
Страница 24: ...System Data Flow 1 8 Service Guide...
Страница 120: ...AIX and Physical Location Code Reference Table 3 48 Service Guide...
Страница 121: ...Chapter 3 Error Code to FRU Index 3 49...
Страница 208: ...5 40 Service Guide...
Страница 211: ...Covers Removal 1 Open the door Chapter 6 Removal and Replacement Procedures 6 3...
Страница 217: ...b Remove the I O planar cover Chapter 6 Removal and Replacement Procedures 6 9...
Страница 222: ...5 Close the door 6 14 Service Guide...
Страница 231: ...4 Remove the screw holding the adapter Chapter 6 Removal and Replacement Procedures 6 23...
Страница 240: ...4 Remove the Processor card s as described in Processor Card on page 6 35 6 32 Service Guide...
Страница 247: ...Chapter 6 Removal and Replacement Procedures 6 39...
Страница 251: ...Replacement Replace in reverse order Chapter 6 Removal and Replacement Procedures 6 43...
Страница 255: ...Chapter 7 Parts Information Chapter 7 Parts Information 7 1...
Страница 256: ...7 2 Service Guide...
Страница 258: ...Note See IBM RS 6000 Diagnostic Information for Multiple Bus Systems for part numbers 7 4 Service Guide...
Страница 278: ...A 16 Service Guide...
Страница 318: ...C 4 Service Guide...
Страница 333: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations D 15...
Страница 340: ...D 22 Service Guide...
Страница 344: ...E 4 Service Guide...
Страница 353: ...VPD vital product data 3 93 Index X 9...
Страница 354: ...X 10 Service Guide...
Страница 356: ...X 12 Service Guide...
Страница 357: ......