Telephone Number Setup Menu
1. Service Center Telephone Number:
Currently Unassigned
2. Customer Administration Center Telephone Number:
Currently Unassigned
3. Digital Pager Telephone Number:
Currently Unassigned
4. Customer Voice Telephone Number:
Currently Unassigned
5. Customer System Telephone Number:
Currently Unassigned
98. Return to Previous Menu
á
ñ
Service Center Telephone Number is the number of the service center
computer. The service center usually includes a computer that takes calls from
servers with call-out capability. This computer is referred to as "the catcher."
The catcher expects messages in a specific format to which Service Processor
conforms. For more information about the format and catcher computers, refer
to the README file in the AIX
/usr/samples/syscatch
directory. Contact your
service provider for the correct telephone number to enter here. Until you have
that number, leave this field blank.
Customer Administration Center Telephone Number is the number of the
System Administration Center computer (catcher) that receives problem calls
from servers. Contact your system administrator for the correct telephone
number to enter here. Until you have that number, leave this field blank.
Digital Pager Telephone Number is the number for a pager carried by
someone who will respond to problem calls from your server. Contact your
administration center representative for the correct telephone number to enter
here. For test purposes, enter your telephone number here. You can change it
later when testing is complete.
Note: Some modems, such as IBM 7857-017, are not designed for the paging
function. Although they can be used for paging, they will return an error
message when they do not get the expected response from another
modem. Therefore, even though the paging was successful, the error
message will cause the Service Processor to retry, continuing to place
pager calls for the number of retries specified in the Call-Out policy Setup
Menu. These retries result in redundant pages.
Appendix B. Service Processor Menus
B-19
Содержание RS6000 - 7026 - H70
Страница 1: ...RS 6000 7025 F50 Series IBM Service Guide SA38 0541 01...
Страница 6: ...vi Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 18: ...Rear View 1 2 Service Guide...
Страница 23: ...Operator Panel Chapter 1 Reference Information 1 7...
Страница 24: ...System Data Flow 1 8 Service Guide...
Страница 120: ...AIX and Physical Location Code Reference Table 3 48 Service Guide...
Страница 121: ...Chapter 3 Error Code to FRU Index 3 49...
Страница 208: ...5 40 Service Guide...
Страница 211: ...Covers Removal 1 Open the door Chapter 6 Removal and Replacement Procedures 6 3...
Страница 217: ...b Remove the I O planar cover Chapter 6 Removal and Replacement Procedures 6 9...
Страница 222: ...5 Close the door 6 14 Service Guide...
Страница 231: ...4 Remove the screw holding the adapter Chapter 6 Removal and Replacement Procedures 6 23...
Страница 240: ...4 Remove the Processor card s as described in Processor Card on page 6 35 6 32 Service Guide...
Страница 247: ...Chapter 6 Removal and Replacement Procedures 6 39...
Страница 251: ...Replacement Replace in reverse order Chapter 6 Removal and Replacement Procedures 6 43...
Страница 255: ...Chapter 7 Parts Information Chapter 7 Parts Information 7 1...
Страница 256: ...7 2 Service Guide...
Страница 258: ...Note See IBM RS 6000 Diagnostic Information for Multiple Bus Systems for part numbers 7 4 Service Guide...
Страница 278: ...A 16 Service Guide...
Страница 318: ...C 4 Service Guide...
Страница 333: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations D 15...
Страница 340: ...D 22 Service Guide...
Страница 344: ...E 4 Service Guide...
Страница 353: ...VPD vital product data 3 93 Index X 9...
Страница 354: ...X 10 Service Guide...
Страница 356: ...X 12 Service Guide...
Страница 357: ......