3-1 (Page 6 of 24). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
25010xxx
Flash Update Problem
25010000
No diskette in drive.
Insert diskette containing firmware
image.
25010001
Diskette seek error.
1. Retry function.
2. Replace diskette drive.
3. Replace diskette cable.
4. Replace I/O board. (See notes on
3-1.)
25010002
Diskette in drive does not contain an
*.IMG file.
Insert diskette with firmware update file.
25010003
Cannot open OPENPROM package.
Replace I/O board. (See notes on
3-1.)
25010004
Cannot find OPENPROM node.
Replace I/O board. (See notes on
3-1.)
25010006
System id does not match image
system id.
Make sure correct firmware update
diskette is being used with this system.
25010007
Image has bad CRC.
Replace firmware updated diskette.
25010008
Flash is write protected, update
cancelled.
1. Turn off, turn on system unit and
retry.
2. Replace I/O board. (See notes on
3-1.)
25010009
Flash module is unsupported or not
recognized.
Make sure correct firmware update
diskette is being used with this system.
2501000A
Flash write protected.
1. Turn off, turn on system unit, retry.
2. Replace I/O board. (See notes on
3-1.)
25A0xxx0
L2 Cache controller problem.
1. Replace the CPU card.
2. Replace the System board.
See error code 2B2xxx22 for xxx
definitions.
25A0xxx1
L2 Cache controller problem.
1. Replace the CPU card.
2. Replace the System board.
See error code 2B2xxx22 for xxx
definitions.
25A1xxx1
L2 SRAM failure
Replace the CPU card.
See error code 2B2xxx22 for xxx
definitions.
Chapter 3. Error Code to FRU Index
3-7
Содержание RS6000 - 7026 - H70
Страница 1: ...RS 6000 7025 F50 Series IBM Service Guide SA38 0541 01...
Страница 6: ...vi Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 18: ...Rear View 1 2 Service Guide...
Страница 23: ...Operator Panel Chapter 1 Reference Information 1 7...
Страница 24: ...System Data Flow 1 8 Service Guide...
Страница 120: ...AIX and Physical Location Code Reference Table 3 48 Service Guide...
Страница 121: ...Chapter 3 Error Code to FRU Index 3 49...
Страница 208: ...5 40 Service Guide...
Страница 211: ...Covers Removal 1 Open the door Chapter 6 Removal and Replacement Procedures 6 3...
Страница 217: ...b Remove the I O planar cover Chapter 6 Removal and Replacement Procedures 6 9...
Страница 222: ...5 Close the door 6 14 Service Guide...
Страница 231: ...4 Remove the screw holding the adapter Chapter 6 Removal and Replacement Procedures 6 23...
Страница 240: ...4 Remove the Processor card s as described in Processor Card on page 6 35 6 32 Service Guide...
Страница 247: ...Chapter 6 Removal and Replacement Procedures 6 39...
Страница 251: ...Replacement Replace in reverse order Chapter 6 Removal and Replacement Procedures 6 43...
Страница 255: ...Chapter 7 Parts Information Chapter 7 Parts Information 7 1...
Страница 256: ...7 2 Service Guide...
Страница 258: ...Note See IBM RS 6000 Diagnostic Information for Multiple Bus Systems for part numbers 7 4 Service Guide...
Страница 278: ...A 16 Service Guide...
Страница 318: ...C 4 Service Guide...
Страница 333: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations D 15...
Страница 340: ...D 22 Service Guide...
Страница 344: ...E 4 Service Guide...
Страница 353: ...VPD vital product data 3 93 Index X 9...
Страница 354: ...X 10 Service Guide...
Страница 356: ...X 12 Service Guide...
Страница 357: ......