6.
Enter
any
requested
passwords.
7.
Select
Setup
Remote
IPL
(Initial
Program
Load)
.
8.
Enter
the
client
address,
server
address,
gateway
address
(if
applicable),
and
subnet
mask.
Exit
to
the
Network
Parameters
screen.
9.
If
the
NIM
server
is
set
up
to
allow
pinging
from
the
client
system,
use
the
ping
utility
in
the
RIPL
utility
to
verify
that
the
client
system
can
ping
the
NIM
server.
Under
the
ping
utility,
choose
the
network
adapter
that
provides
the
attachment
to
the
NIM
server
to
do
the
ping
operation.
If
the
ping
returns
with
an
OK
prompt,
the
client
is
prepared
to
boot
from
the
NIM
server.
If
ping
returns
with
a
FAILED
prompt,
the
client
cannot
proceed
with
the
NIM
boot.
To
do
a
one-time
boot
of
the
network
adapter
attached
to
the
NIM
server
network,
do
the
following:
1.
Exit
to
the
SMS
Main
screen.
2.
Select
Select
Boot
Options
.
3.
Select
Install
or
Boot
a
Device
.
4.
On
the
Select
Device
Type
screen,
select
Network
.
5.
Set
the
network
parameters
for
the
adapter
from
which
you
want
to
boot.
6.
Exit
completely
from
SMS.
The
system
starts
loading
packets
while
doing
a
bootp
from
the
network.
Follow
the
instructions
on
the
screen
to
select
the
system
console.
v
If
Diagnostics
Operating
Instructions
Version
x.x.x
displays,
standalone
diagnostics
have
loaded
successfully.
v
If
the
operating
system
login
prompt
displays,
standalone
diagnostics
did
not
load.
Check
the
following
items:
–
The
network
parameters
on
the
client
may
be
incorrect.
–
Cstate
on
the
NIM
server
may
be
incorrect.
–
Network
problems
might
be
preventing
you
from
connecting
to
the
NIM
server.
Running
System
Verification
When
the
Diagnostic
Operating
Instructions
display,
do
the
following
to
run
system
verification:
1.
Press
Enter.
2.
If
the
terminal
type
is
requested,
you
must
use
the
Initialize
Terminal
option
on
the
Function
Selection
menu
to
initialize
the
operating
system
before
you
can
continue
with
the
diagnostics.
Note:
If
you
use
a
virtual
terminal
on
the
HMC
and
you
are
asked
to
define
the
terminal
type,
the
virtual
terminal
is
considered
a
VT320.
3.
Select
the
System
Verification
option
on
the
Diagnostic
Mode
Selection
menu.
4.
To
run
a
general
checkout
of
all
installed
resources,
select
the
All
Resource
option
on
the
Diagnostic
Selection
menu.
Follow
the
instructions
on
the
screen
to
complete
the
checkout
procedure.
To
check
one
particular
resource,
select
that
resource
on
the
Diagnostic
Selection
menu.
The
checkout
program
ends
with
either
of
the
following
results:
v
The
Testing
Complete
screen
displays
a
message
stating
No
trouble
was
found
.
v
The
A
Problem
Was
Detected
On
(Time
Stamp)
menu
displays,
with
either
a
service
request
number
(SRN)
or
an
error
code.
Make
a
note
of
any
codes
displayed
on
the
display
or
operator
panel.
To
perform
additional
system
verification,
go
to
“Performing
Additional
System
Verification”
on
page
36.
To
exit
diagnostics,
go
to
“Stopping
the
Diagnostics”
on
page
36.
Chapter
3.
Verifying
the
Hardware
Operation
35
Содержание pSeries 650
Страница 1: ...pSeries 650 Installation Guide SA38 0610 03 ERserver...
Страница 2: ......
Страница 3: ...pSeries 650 Installation Guide SA38 0610 03 ERserver...
Страница 8: ...vi Eserver pSeries 650 Installation Guide...
Страница 12: ...x Eserver pSeries 650 Installation Guide...
Страница 14: ...xii Eserver pSeries 650 Installation Guide...
Страница 22: ...6 Eserver pSeries 650 Installation Guide...
Страница 138: ...122 Eserver pSeries 650 Installation Guide...
Страница 142: ...126 Eserver pSeries 650 Installation Guide...
Страница 150: ...134 Eserver pSeries 650 Installation Guide...
Страница 152: ...136 Eserver pSeries 650 Installation Guide...
Страница 164: ...148 Eserver pSeries 650 Installation Guide...
Страница 170: ...154 Eserver pSeries 650 Installation Guide...
Страница 182: ...166 Eserver pSeries 650 Installation Guide...
Страница 186: ...170 Eserver pSeries 650 Installation Guide...
Страница 189: ......
Страница 190: ...Part Number 80P3834 Printed in USA November 2003 SA38 0610 03 1P P N 80P3834...