¦ Location ¦ Description ¦
+----------------------+---------------------------------------------¦
¦ 1-8 ¦ Disk drive logic card ¦
+--------------------------------------------------------------------¦
¦ Note: See the "Failing Item Table" in topic 3.3 for the correct ¦
¦ part number for a specific FRU part. ¦
+--------------------------------------------------------------------+
Note: Where indicated, exchange the disk drive logic card using the
same disk enclosure.
12. Did the exchange procedure "Disk Drive Logic Card" with the new logic
card complete without an error?
Yes No
Go to step 16.
13. The disk drive on which you exchanged the disk drive logic should be
exchanged. Wait until the automatic data rebuild is completed. This
can take up to 40 minutes and is complete when the Unit Ready light
stops blinking.
Use the procedure "Disk Drive" in topic 4.5.1 to exchange the disk
drive. Then return to step 14 in this procedure.
14. Using the control panel, set the 3514 online by entering the following
sequence:
9 0 7 9 PICTURE 213
15. After 3 minutes, is *000 displayed on the 3514 control panel?
Yes No
Go to step "Starting Problem Analysis" in topic 1.2.
End of procedure.
16. Warning: Some data on the 3514 will be damaged.
Using the exchange procedure "Disk Drive" in topic 4.5.1, exchange the
second failing disk drive as indicated by the second rightmost
position of the URC (5tpx) where p = slots 1 through 7.
+--------------------------------------------------------------------+
¦ Location ¦ Description ¦
+----------------------+---------------------------------------------¦
¦ 1-8 ¦ Disk drive assembly ¦
+--------------------------------------------------------------------¦
¦ Note: See the "Failing Item Table" in topic 3.3 for the correct ¦
¦ part number for a specific FRU part. ¦
+--------------------------------------------------------------------+
17. Using the control panel, set the 3514 online by entering the following
sequence:
9 0 7 9 PICTURE 214
18. After 3 minutes, is *000 displayed on the 3514 control panel?
Yes No
Go to step "Starting Problem Analysis" in topic 1.2.
19. The data on the 3514 must be recovered using the latest backup data
available. See your system unit and operating system manuals for
instructions.
Do not attempt to save data from the failing 3514.
End of procedure.
20. The disk drive that you reset should be exchanged. Wait until the
automatic data rebuild is completed. This can take up to 40 minutes
and is complete when the Unit Ready light stops blinking.
Use the procedure "Disk Drive" in topic 4.5.1 to exchange the disk
3514 Service Information
URC 5tpx
¦ Copyright IBM Corp. 1992, 1993
3.5.18.1 - 2