sequence on the control panel:
a. 9 PICTURE 185
Note: This command can take up to 80 minutes to complete. Data
on this disk drive will be built again.
b. As the command processes, the display indicates the percent
completed.
c. When the operation ends without error, a quick status of the disk
drives is displayed.
Example:
+-----------------+
¦ 1 2 3 _ 5 _ 7 _ ¦ Indicates the disk
+-----------------+ configuration
1 2 3 4 5 6 7 8
d. If the 3514 detects an error during the 4 2 9 n command, a return
code is displayed.
To determine if further action is required, go to "Control Panel
Command Return Code Information" in topic 3.4.
+-----------------+
¦ 4 2 9 n x x ¦ Return Code x x
+-----------------+ on disk drive n.
1 2 3 4 5 6 7 8
Note: A return code of DE may indicate an address jumper or cable
is not installed correctly.
e. Press the * (Home) key to clear the display and return it to ready
status (*000).
Warning: Do not continue with step 19 until the exchange command
is complete.
19. Attach the front EMC shield.
Note: Engage both thumbscrews before you tighten either screw.
PICTURE 186
20. Restore the control panel to operating position and tighten screw 1 :
PICTURE 187
21. Install the front cover (see "Front Cover Removal or Installation
Procedure" in topic 4.3).
22. The data on the 3514 must be recovered using the latest backup data
available. See your system unit and operating system manuals for
instructions.
Do not attempt to save data from the failing 3514.
End of procedure.
3514 Service Information
URC C9p7 C9p8
¦ Copyright IBM Corp. 1992, 1993
3.5.15.1 - 3