in odd-numbered slots (1, 3, 5, or 7).
20. Set the Power switch to the On position.
21. After 3 minutes, is *000, B000, or BBA0 displayed on the Data display?
Yes No
Go to "Starting Problem Analysis" in topic 1.2.
22. From your computer system, run the diagnostic test programs for the
3514/A Array Adapter. (See the 3514 Quick Reference Manual SA21-9613
for instructions on running diagnostics.)
Did the test programs run without error?
Yes No
Go to "Starting Problem Analysis" in topic 1.2.
23. Is *000 displayed on the Data display?
Yes No
Go to "Starting Problem Analysis" in topic 1.2.
End of procedure.
24. The data on the missing disk drives cannot be restored. To make the
3514 operational again, do the following:
Using the control panel, set the 3514 offline by entering the
following sequence:
9 1 7 0 PICTURE 110
A display of 90FF indicates that the 3514 is offline.
25. Install the new disk drives into the missing disk drive slots using
the procedure "Reset Disk Drive" in topic 4.5.7.
This will make the new disk drives part of the 3514 configuration. No
data will be written to the new disk drives in this step.
Return here when you have completed the procedure "Reset Disk Drive"
in topic 4.5.7.
26. Using the control panel, set the 3514 online by entering the following
sequence:
9 0 7 9 PICTURE 111
End of procedure.
3514 Service Information
URC CE29
¦ Copyright IBM Corp. 1992, 1993
3.5.6.1 - 3