Replacing a power supply in the 8001-12C, 8001-22C, 8005-12N, or 8005-22N
Learn how to replace power supplies in the IBM Power System S821LC (8001-12C), the IBM Power
System S822LC for Big Data (8001-22C), the IBM CS821 (8005-12N), or the IBM CS822 (8005-22N) systems.
Procedure
1.
Ensure that you have the electrostatic discharge (ESD) wrist strap attached. If not, attach it now.
2.
Align the power supply with the bay as shown in Figure 63. The fan is on the left; the plug is on the
right. Slide the power supply into the system until the latch locks in place.
3.
Reconnect the power cord. For instructions, see “Connecting the power cords to an 8001-12C,
8001-22C, 8005-12N, or 8005-22N system” on page 108.
Removing and replacing covers on an 8001-22C or 8005-22N system
Learn how to remove and replace the covers for an IBM Power System S822LC for Big Data (8001-22C) or
the IBM CS822 (8005-22N) system so that you can access the hardware parts or service the system.
Removing the service access cover from an 8001-22C or 8005-22N system
Learn how to remove the service access cover from an IBM Power System S822LC for Big Data
(8001-22C) or the IBM CS822 (8005-22N) system.
About this task
Attention:
For safety, airflow purposes and thermal performance, the service access cover must be
installed and fully seated before you power on the system.
Procedure
1.
Ensure that you removed both power cords from the system. For instructions, see “Disconnecting the
power cords from an 8001-12C, 8001-22C, 8005-12N, or 8005-22N system” on page 107.
(L005)
Figure 63. Replacing a power supply in the system
102
Power Systems: Installing the IBM Power System S822LC for Big Data (8001-22C)
Содержание Power Systems 8001-22C
Страница 1: ...Power Systems Installing the IBM Power System S822LC for Big Data 8001 22C IBM...
Страница 2: ......
Страница 3: ...Power Systems Installing the IBM Power System S822LC for Big Data 8001 22C IBM...
Страница 16: ...xiv Power Systems Installing the IBM Power System S822LC for Big Data 8001 22C...
Страница 136: ...120 Power Systems Installing the IBM Power System S822LC for Big Data 8001 22C...
Страница 137: ......
Страница 138: ...IBM Printed in USA...