g.
Replace the screw to secure the tail-stock.
h.
If you have a SAS super capacitor carrier, insert that carrier (A) in position 2 of the PCIe adapter
riser (B) as shown in Figure 49.
i.
Insert the PCIe riser into the chassis as shown in Figure 50 on page 82.
1)
Retract the retaining pin (B) so the arrow points to the system.
2)
Insert the riser, using the slots and alignment pins (A) to properly insert the riser. Push the riser
firmly into the system backplane.
3)
Set the retaining pin (B) to secure the riser.
Figure 48. Inserting an adapter into position 3 of the PCIe riser
Figure 49. Inserting a SAS super capacitor carrier into position 2 of the riser
Installing and configuring the system
81