Specifications and features
The following table provides a summary of the features and specifications for your
Netfinity 6000R server.
Microprocessor:
•
Intel® Pentium® III Xeon™
•
32 KB Level-1 cache
•
1 MB Level-2 cache (min.)
•
100 MHz front-side bus
(FSB)
•
Supports up to four
microprocessors
Memory
:
•
Maximum: 16 GB
•
Type: ECC, SDRAM,
Registered DIMMs
•
Slots: 4-way interleaved, 16
slots
Drives standard:
•
Diskette: 1.44 MB
•
CD-ROM: 40X IDE
Expansion bays
:
Slim-high hot-swap
•
Standard: Three
•
Optional: Three
Active™ PCI expansion slots:
•
One 33 MHz/32-bit
•
Three 66 MHz/64-bit
•
Two 33 MHz/64-bit
Hot-swap power supplies:
270 W (115-230 V ac)
•
Minimum: One
•
Maximum: Three
Redundant cooling:
Six hot-swap fans
Size (4 U)
•
Height: 178 mm (7 in.)
•
Depth: 711.2 mm (28 in.)
•
Width: 482.6 mm (19 in.)
•
Weight: 34.9 kg (77 lb.) to
50.4 kg (111 lb.) depending
upon configuration
Integrated functions:
•
Netfinity Advanced System
Management processor with
Light Path Diagnostics
•
Dual channel Ultra160 SCSI
controller (one internal and
one external channel) (non-
RAID)
•
One 10BASE-T/100BASE-
TX AMD Ethernet controller
•
Two serial ports
•
One parallel port
•
Two Universal Serial Bus
ports
•
Keyboard port
•
Mouse port
•
Video port
Acoustical noise emissions:
•
Sound power, idling: 6.3 bel
maximum
•
Sound power, operating: 6.3
bel maximum
•
Sound pressure, operating:
47 dBa maximum
Video:
•
S3 video controller
•
Compatible with SVGA and
VGA
•
8 MB video memory
Environment:
•
Air temperature:
— Server on: 10
°
to 35
°
C
(50
°
to 95
°
F). Altitude: 0
to 914 m (3000 ft.)
— Server on: 10
°
to 32
°
C
(50
°
to 89.6
°
F). Altitude:
914 m (3000 ft.) to 2133
m (7000 ft.)
— Server off: 10
°
to 43
°
C
(50
°
to 110
°
F).
Maximum altitude: 2133
m (7000 ft.)
•
Humidity:
— Server on: 8% to 80%
— Server off: 8% to 80%
Heat output:
Approximate heat output in
British Thermal Units (BTU) per
hour
•
Minimum configuration: 461
BTU (0.14 kilowatts)
•
Maximum configuration:
1796 BTU (0.53 kilowatts)
Electrical input:
•
Sine-wave input (50-60 Hz)
required
•
Input voltage low range:
— Minimum: 90 V ac
— Maximum: 137 V ac
•
Input voltage high range:
— Minimum: 180 V ac
— Maximum: 265 V ac
•
Input kilovolt-amperes
(kVA) approximately:
— Minimum: 0.08kVA
— Maximum: 0.52 kVA
Table 1. Features and Specifications
Содержание Netfinity 6000R
Страница 1: ...IBM IBM Netfinity 6000R Installation Guide SC09 N820 30...
Страница 2: ......
Страница 3: ...IBM IBM Netfinity 6000R Installation Guide...
Страница 6: ...IBM Netfinity 6000R Installation Guide...
Страница 11: ...ix Statement 4 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs CAUTION Use safe practices when lifting...
Страница 18: ...6 IBM Netfinity 6000R Installation Guide...
Страница 36: ...24 IBM Netfinity 6000R Installation Guide...
Страница 46: ...34 IBM Netfinity 6000R Installation Guide...
Страница 62: ...50 IBM Netfinity 6000R Installation Guide...
Страница 64: ...52 IBM Netfinity 6000R Installation Guide...
Страница 65: ......