v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 8850,” on page 53 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
199
Processor power rating unsupported.
1. (Trained service technician only) Make sure that
the microprocessor that was just installed has a
supported power rating. If the power rating is not
supported, replace the microprocessor with one
that has a supported power rating.
2. Update BIOS code.
3. (Trained service technician only) Replace the
microprocessor.
201
Memory test error.
1. Update BIOS code and rerun diagnostics.
2. Reseat the DIMMs.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. DIMMs
b. (Trained service technician only) System
board assembly
229
Cache error.
1. Reseat the following components:
a. (Trained service technician only)
Microprocessor 1
b. (Trained service technician only)
Microprocessor 2
2. Replace the components listed in step 1 one at a
time, in the order shown, restarting the server
each time.
289
DIMM disabled by user or system.
1. If the DIMM was disabled by the user, run the
Configuration/Setup Utility program and enable
the DIMM.
2. Reseat the disabled DIMM.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. Disabled DIMM
b. (Trained service technician only) System
board assembly
20
AMD Opteron LS20 Type 8850 for IBM BladeCenter: Problem Determination and Service Guide
Содержание LS20 - BladeCenter - 8850
Страница 1: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 14: ...xii AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 72: ...58 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 104: ...90 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 114: ...100 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 115: ......
Страница 116: ...Part Number 49Y0167 Printed in USA 1P P N 49Y0167...