Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 8850,” on page 53 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Beep code
Description
Action
1-2-2
DMA initialization failed.
(Trained service technician only) Replace the
system board assembly.
1-2-3
DMA page register write/read failed.
(Trained service technician only) Replace the
system board assembly.
1-2-4
RAM refresh verification failed.
1. Reseat the DIMMs.
2. Replace the following components one at a
time, in the order shown, restarting the
server each time.
a. DIMMs
b. (Trained service technician only) System
board assembly
1-3-1
First 64K RAM test failed.
1. Reseat the DIMMs.
2. Replace the following components one at a
time, in the order shown, restarting the
server each time.
a. DIMMs
b. (Trained service technician only) System
board assembly
1-3-2
First 64K RAM parity test failed.
1. Reseat the DIMMs.
2. Replace the following components one at a
time, in the order shown, restarting the
server each time.
a. DIMMs
b. (Trained service technician only) System
board assembly
2-1-1
Secondary DMA register failed.
(Trained service technician only) Replace the
system board assembly.
2-1-2
Primary DMA register failed.
(Trained service technician only) Replace the
system board assembly.
2-1-3
Primary interrupt mask register failed.
(Trained service technician only) Replace the
system board assembly.
2-1-4
Secondary interrupt mask register failed.
(Trained service technician only) Replace the
system board assembly.
2-2-1
Interrupt vector loading failed.
(Trained service technician only) Replace the
system board assembly.
Chapter 2. Diagnostics
11
Содержание LS20 - BladeCenter - 8850
Страница 1: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 14: ...xii AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 72: ...58 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 104: ...90 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 114: ...100 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 115: ......
Страница 116: ...Part Number 49Y0167 Printed in USA 1P P N 49Y0167...