v
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v
See Chapter 4, “Parts listing, Types 8014, 8028 and 1916,” on page 25 to determine
which components are CRUs and which components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be
performed only by a trained service technician.
Error message
Action
Internal error CPU fault
Make sure that all of the software and the
drivers are at the latest levels. Go to
http://www.ibm.com/systems/support/.
CPU over temperature
Make sure that the blade server is
sufficiently cooled.
CPU fault
(Trained service technician only) Replace the
microprocessor - See “Removing a
microprocessor and heat sink” on page 60
and “Installing a microprocessor and heat
sink” on page 62.
CPU disabled
(Trained service technician only) Replace the
microprocessor - See “Removing a
microprocessor and heat sink” on page 60
and “Installing a microprocessor and heat
sink” on page 62.
Invalid CPU configuration
Make sure that microprocessor is supported
and compatible.
VRD 5d power good fault
1.
Remove the blade server from the
BladeCenter; then, reinstall it. See
“Removing the blade server from the
BladeCenter unit” on page 33 and
“Installing the blade server in a
BladeCenter unit” on page 34.
2.
(Trained service technician only) Replace
the system-board assembly - See
“Removing the system-board assembly”
on page 65 and “Installing the
system-board assembly” on page 66
Hard drive
xx
removal detected
Replace storage drive
xx
. Depending on
your storage drive type, see one of the
following:
v
Fixed-storage drive: “Removing a
fixed-storage drive” on page 41 and
“Installing a fixed-storage drive” on page
42
v
Hot-swap storage drive: “Installing a
hot-swap storage drive” on page 44 and
“Removing a hot-swap storage drive” on
page 43.
Hard drive
xx
fault
Information only. No action is required.
Chapter 6. Diagnostics
85
Содержание HS12 - BladeCenter - 8028
Страница 1: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 36: ...24 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 186: ...174 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 190: ...178 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 198: ...186 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 203: ......
Страница 204: ...Part Number 60Y1601 Printed in USA 1P P N 60Y1601...