v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 4, “Parts listing, Types 8014, 8028 and 1916,” on page 25 to determine which components are CRUs
and which components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
1804
No more memory (below 1 MB) available.
1.
Run the Configuration/Setup Utility program
and make sure that interrupt resource settings are
correct. See “Using the Configuration/Setup
Utility program” on page 15.
2.
Remove each I/O expansion card one at a time,
restarting the blade server each time, until the
problem is isolated. See “Turning off the blade
server” on page 10“Removing an I/O expansion
card” on page 50 and “Turning on the blade
server” on page 9.
3.
If an optional expansion unit is installed, reseat it
- See “Removing an optional expansion unit” on
page 37 and “Installing an optional expansion
unit” on page 38.
4.
Replace the following components one at a time,
in the order shown, restarting the blade server
each time:
a.
Failed I/O expansion card - See “Removing
an I/O expansion card” on page 50
and“Installing an I/O expansion card” on
page 51.
b.
Optional expansion unit (if one is installed) -
See “Removing an optional expansion unit”
on page 37 and “Installing an optional
expansion unit” on page 38.
c.
(Trained service technician only) System-board
assembly - See “Removing the system-board
assembly” on page 65 and “Installing the
system-board assembly” on page 66.
Chapter 6. Diagnostics
97
Содержание HS12 - BladeCenter - 8028
Страница 1: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 36: ...24 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 186: ...174 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 190: ...178 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 198: ...186 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Страница 203: ......
Страница 204: ...Part Number 60Y1601 Printed in USA 1P P N 60Y1601...