Chapter
11.
Configuring
the
terminal
server
after
device
replacement
If
you
can
successfully
ping
the
In-Reach
LX-4000
(32-port,
48-port)
terminal
server,
no
further
action
is
needed.
The
terminal
server
has
been
properly
configured.
Note:
Do
not
try
to
define
ports
21
through
40
on
a
terminal
server
with
only
20
ports.
If
you
cannot
ping
the
terminal
server,
then
configure
the
device:
1.
Connect
a
laptop
computer
running
a
terminal
emulation
program
(such
as
HyperTerminal)
to
the
command
port
on
the
back
panel
of
the
terminal
server
using
a
DB9
to
RJ45
serial
cable.
2.
Set
the
terminal
configuration
to
the
following
settings:
v
9600
baud
v
8
bits
v
1
stop
bit
v
no
parity
v
no
flow
control
3.
Attach
a
serial
terminal
to
the
command
port.
The
default
command
port
is
the
last
port,
either
port
20
or
port
40
depending
on
the
size
of
the
terminal
server.
4.
Turn
on
the
terminal
server
and
press
Enter
repeatedly
until
you
see
the
*Login>*
command
prompt,
and
type
access
.
No
readable
characters
are
visible.
5.
Press
Enter
.
6.
At
the
*Username>*
command
prompt,
type
system
and
press
Enter
.
The
In-Reach
directory
prompt
displays.
7.
At
the
In-Reach>
command
prompt,
type
set
priv
and
press
Enter
.
8.
At
the
*Password>*
command
prompt,
type
system
.
9.
At
the
*In-Reach>*
command
prompt,
type
show
ip
to
see
the
current
network
settings.
10.
To
set
the
IP
address,
type
define
ip
address
xxx.xxx.xxx.xxx
.
11.
To
set
the
gateway
address,
type
define
ip
primary
gateway
address
xxx.xxx.xxx.xxx
.
12.
To
set
the
subnet
mask,
type
define
ip
subnet
mask
xxx.xxx.xxx.xxx
.
13.
To
save
the
configuration
and
restart
the
terminal
server,
type
init
delay
0
.
If
the
terminal
server
does
not
already
have
an
IP
address,
it
might
need
further
configuration
so
the
serial
ports
can
operate
properly.
Complete
the
following
steps:
1.
Telnet
to
the
IP
address
assigned
to
the
terminal
server.
2.
At
the
*Login>*
command
prompt,
type
access
.
3.
At
the
*Username>*
command
prompt,
type
system
.
4.
At
the
*In-Reach>*
command
prompt,
type
set
priv
.
5.
At
the
*Password>*
command
prompt,
type
system
.
6.
At
the
*In-Reach_Priv>*
command
prompt,
define
the
ports
by
entering
the
following:
In-Reach_Priv>define
port
1-20
access
remote
In-Reach_Priv>define
port
21-40
access
remote
In-Reach_Priv>define
port
1-20
flow
control
enable
In-Reach_Priv>define
port
21-40
flow
control
enable
In-Reach_Priv>define
port
1-20
speed
9600
In-Reach_Priv>define
port
21-40
speed
9600
In-Reach_Priv>define
port
1-20
que
disable
©
Copyright
IBM
Corp.
2004
59
Содержание eserver Cluster 1350
Страница 1: ...IBM Eserver Cluster 1350 Installation and Service Guide ERserver...
Страница 2: ......
Страница 3: ...IBM Eserver Cluster 1350 Installation and Service Guide ERserver...
Страница 26: ...10 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 82: ...66 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 86: ...70 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 88: ...72 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 90: ...74 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 94: ...78 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 98: ...82 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 104: ...88 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 114: ...98 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 120: ...104 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 121: ......
Страница 122: ...Part Number 25K8407 Printed in USA 1P P N 25K8407...