Disk
drive
failure
on
a
storage
node
Use
the
following
troubleshooting
information
about
disk
drive
failures
on
a
storage
node.
The
xSeries
345
and
xSeries
360
support
hot
swapping
of
hard
disks.
To
replace
a
failing
hard
disk
on
the
storage
node:
1.
Remove
the
failing
hard
disk
by
sliding
it
out
through
the
front
panel
opening.
2.
Slide
the
replacement
disk
drive
into
the
open
slot.
The
drive
will
rebuild
automatically
on
a
mirrored
system.
To
rebuild
the
storage
node,
if
the
system
is
not
mirrored,
enter
the
following
command
at
the
management
node
command
line
prompt:
installstorage
1
System
board
failures
Use
the
following
troubleshooting
information
about
system
board
failures.
1.
Replace
the
system
board.
2.
Flash
the
system
BIOS
to
the
level
used
in
the
installation.
Refer
to
for
a
listing
of
the
software
and
firmware
levels
used
in
the
Cluster
1350.
3.
Flash
the
Diagnostics
to
match
the
BIOS
level.
Refer
to
for
a
listing
of
the
software
and
firmware
levels
used
in
the
Cluster
1350.
4.
Flash
the
onboard
ASM
to
the
current
level.
Refer
to
for
a
listing
of
the
software
and
firmware
levels
used
in
the
Cluster
1350.
5.
Perform
the
following
configuration
settings:
v
Devices
and
I/O
Ports:
PORT
3F8,
IRQ4
v
Remote
Console
Redirection:
Enabled,
COM1,
9600,
8,
None,
1,
VT100,
Enabled
v
Boot
sequence:
Diskette
Drive,
CD
ROM,
Network,
Hard
Drive
0,
Boot
Fail
Count:
DISABLED
v
Set
the
remote
control
password
if
a
Remote
Supervisor
Adapter
card
is
installed
in
this
node
(xSeries
335,
xSeries
345,
xSeries
360
only).
v
If
you
are
replacing
an
HS20
BladeCenter
with
a
serial
port
option,
make
sure
that
switch
7
in
the
switchblock
is
turned
on
.
v
Update
the
cluster
software
with
the
new
MAC
address
associated
with
the
new
system
board
or
Blade
card
you
installed.
–
To
get
the
MAC
address
of
eth0
for
the
new
component,
use
the
CSM
command:
ifconfig
–
To
update
the
cluster
software,
use
the
CSM
command:
chnode
<nodename>
InstallAdaptorMacaddr=<new
MAC
(xx:xx:xx:xx:xx:xx)>,Any
System
.
Contact
support
for
any
setup
or
IP
configurations
that
need
to
be
performed.
6.
Turn
the
customer
over
to
support
for
any
additional
tasks
needed
to
restore
the
node
to
full
functionality.
xSeries
335
problems
In
a
xSeries
335
with
an
Remote
Supervisor
Adapter
(RSA)
over
C2T
connection
make
sure
that
the
cluster
node
at
the
beginning
of
the
C2T
chain
has
an
RSA
card,
external
dongle,
and
connection
to
the
onboard
RSA
processor.
BladeCenter
problems
When
the
serial
port
option
is
used
on
a
blade
server
in
the
BladeCenter
it
is
important
to
make
sure
that
switch
number
7
in
the
switchblock
is
set
to
the
ON
52
IBM
Eserver
Cluster
1350
Installation
and
Service
Guide
Содержание eserver Cluster 1350
Страница 1: ...IBM Eserver Cluster 1350 Installation and Service Guide ERserver...
Страница 2: ......
Страница 3: ...IBM Eserver Cluster 1350 Installation and Service Guide ERserver...
Страница 26: ...10 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 82: ...66 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 86: ...70 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 88: ...72 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 90: ...74 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 94: ...78 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 98: ...82 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 104: ...88 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 114: ...98 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 120: ...104 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 121: ......
Страница 122: ...Part Number 25K8407 Printed in USA 1P P N 25K8407...