Table 5. Light Path Diagnostics (continued)
Lit blade-error
LED
Cause
Action
DIMM
x
error
A memory error occurred.
Replace the DIMM indicated by the lit DIMM
failure LED.
Note:
Multiple DIMM LEDs do not necessarily
indicate multiple DIMM failures. If more than
one DIMM LED is lit, reseat or replace one
DIMM at a time until error goes away. Check
the system error log in the BladeCenter
management module for information about the
error.
If the problem remains, have the blade server
serviced.
Processor
x
error
The microprocessor has failed.
Verify that the microprocessor indicated by the
lit LED is installed correctly. (See “Installing an
additional microprocessor” on page 25 for
installation instructions.)
If the problem remains, have the
microprocessor replaced.
Temperature error
The system temperature has exceeded a
threshold level.
1. Check to see if a blower on the
BladeCenter unit has failed. If it has,
replace the fan.
2. Make sure the room temperature is not too
high. (See “Features and specifications” on
page 5 for temperature information.)
If the problem remains, have the blade server
serviced.
System board error The system board has failed
Replace the blade server cover, reinsert the
blade server in the BladeCenter unit, and then
restart the server.
If the problem remains, have the blade server
serviced.
IDE bus
x
error
The IDE bus indicated by the error LED has
failed.
Have the blade server serviced.
NMI error
The system board has failed.
1. Replace the blade server cover, reinsert
the blade server in the BladeCenter unit,
and then restart the server.
2. Check the system error log in the
BladeCenter management module for
information about the error.
If the problem remains, have the blade server
serviced.
Processor
mismatch
The processors do not match.
Verify that microprocessors 1 and 2 have the
same cache size and type and the same clock
speed. Internal and external clock frequencies
must be identical.
If the problem remains, have the blade server
serviced.
64
BladeCenter HS20 Type 8832: Installation and User’s Guide
Содержание BladeCanter HS20
Страница 3: ...BladeCenter HS20 Type 8832 Installation and User s Guide ERserver...
Страница 7: ...Japanese Voluntary Control Council for Interference VCCI statement 83 Index 85 Contents v...
Страница 8: ...vi BladeCenter HS20 Type 8832 Installation and User s Guide...
Страница 14: ...xii BladeCenter HS20 Type 8832 Installation and User s Guide...
Страница 26: ...12 BladeCenter HS20 Type 8832 Installation and User s Guide...
Страница 32: ...18 BladeCenter HS20 Type 8832 Installation and User s Guide...
Страница 58: ...44 BladeCenter HS20 Type 8832 Installation and User s Guide...
Страница 66: ...52 BladeCenter HS20 Type 8832 Installation and User s Guide...
Страница 68: ...54 BladeCenter HS20 Type 8832 Installation and User s Guide...
Страница 98: ...84 BladeCenter HS20 Type 8832 Installation and User s Guide...
Страница 102: ...88 BladeCenter HS20 Type 8832 Installation and User s Guide...
Страница 103: ......
Страница 104: ...Part Number 59P6556 Printed in U S A 1P P N 59P6556...